Download Print this page

Viking C-1000B Technical Practice page 2

Handsfree doorboxes
Hide thumbs Also See for C-1000B:

Advertisement

I
n
s
t
a
l
l
a
t
i
o
I
n
s
t
a
l
l
a
t
i
o
The W-1000 and W-1000-EWP are designed to be flush mounted to the included 4" x 4" x 2" deep plastic rough in box or surface
mounted using optional Viking model VE-5x5. Note: The W-1000/W-1000-EWP will NOT mount to a standard double gang box. The
plastic rough in box (part # 259576) may be purchased separately. Go to www.vikingelectronics.com and click on "Spare Parts".
Front View of Plastic
Rough-In Box (included)
Wire knock out
(2) Standard flat head dry wall
(sheet rock) screws (not included)
3.25"
5.22"
5.14"
Condensation
Front View of Optional
2.25"
VE-5x5 (not included)
B. Mounting the W-2000A and W-2000A-EWP
The W-2000A and W-2000A-EWP are designed to be surface mounted to a single gang box (not included), a standard 4" x 4" elec-
trical junction box (not included), or directly to a wall or flat sided post.
3.40"
1.55"
3.40"
2.35"
Note: For outdoor applications apply a bead of caulk between back panel and wall.
n
n
2.1"
4.0"
(1) .74" dia
Drain Hole
3.0"
Rear View of VE-5x5 (not included)
Front view of the
W-2000A/W-2000A-EWP
3.30"
VIKING
©
To open the speaker box, remove the
two screws from the cover.
*
1/8" thick foam gasket (included)
* Note: Peel off paper liner and
adhere gasket to the back of
the faceplate, centering it over
the four corner mounting holes.
5.0" Typical
Push to Call Button
(4) 6-32 X 3/4" black plated stainless steel,
flat head, hexdrive, screws (included)
Condensation Drain Hole
(4) 0.38" diameter (for gooseneck mounting)
(4) 0.2 x 0.43 slots for double gang box
(2) 0.2 x 0.43 slots for single gang box
The optional VE-5x5 Surface Mount Box is designed to be surface
mounted to a single gang box, double gang box or VE-GNP goose-
3.0" 3.3"
neck pedestal (right).
Back panel of the
W-2000A/W-2000A-EWP
UP
Call
Mount back panel to a wall, a single
gang box or a 4"x4" junction box with
the arrow pointing up.
W-1000-EWP shown in
VE-5x5 with Viking
Model VE-GNP
Gooseneck Pedestal
Caution: When warm air comes in con-
tact with cold surfaces, such as outside
walls, it causes condensation. To help
prevent condensation from accumulat-
ing inside the W-1000, bring conduit into
the bottom of the unit. If this is not pos-
sible, drill a 1/4" diameter hole in the
bottom of the plastic rough-in box.
Need More Information on VE-5x5 or VE-GNP?
?
Call (715) 386-4345 and select 424.
Side view of the
W-2000A/W-2000A-EWP
Attach the cover to the base with
the two included screws as
shown.

Advertisement

loading

This manual is also suitable for: