4. Adding a Master Entry Code
The master entry code is simply an additional entry code in memory position 000. If keyless entry is disabled (when card
readers are used), this master entry code will still function as a keyless code. This is programmed by entering "#," +
the master entry code (4 - 6 digits) + "#" + the memory location 000.
Example: #, 123456 # 000
5. Adding Maintenance Personnel Entry Codes
The maintenance personnel entry codes are simply an additional 5 keyless entry codes in memory locations 251-255.
This is useful when you require additional entry codes for a non-tenant (guard, maintenance worker, etc.) If keyless entry
is disabled (when card readers are used) these entry codes will still function as a keyless code. This is programmed by
entering "#," + the entry code (4 - 6 digits) + "#" + the memory locations 251-255. Example: #, 123456 # 251
6. Deleting the Phone Number and Entry Code for One Memory Location
While in programming dial a "#" + memory location (000 - 255) to clear.
Note: It is not possible to erase only the phone number or the keyless entry number. If either number needs to
be changed, BOTH numbers must be reprogrammed.
7. Deleting All Phone Numbers and Entry Codes
While in programming, enter "###". This will clear all phone numbers, entry codes and set all programming back
to factory settings.
! CAUTION: All phone numbers and entry codes will be permanently erased.
D. Programming Features Quick Reference
Features
Tenant's phone numbers: 001-002 (0-32 digits), 003-250 (0-16 digits) .....................
Tenant's phone numbers and entry codes ................................................................
,
To add a
at any point in the dialing string ............................................................
To add a # at any point in the dialing string ..............................................................
Entry code only (4-6 digits) .......................................................................................
Master entry code (4 - 6 digits) .................................................................................
Maintenance personnel entry codes (4-6 digits) .......................................................
Clear one phone number and entry code .................................................................
PABX line access number: 1-3 digits + 3 sec pause (factory disabled) .....................
Entry point 1 relay activation time (.5-99 sec, 00=.5 sec, factory set to 5 sec) ..........
Entry point 2 relay activation time (.5-99 sec, 00=.5 sec, factory set to 5 sec) ..........
Entry point 3 relay activation time (.5-99 sec, 00=.5 sec, factory set to 5 sec) ..........
Entry point 4 relay activation time (.5-99 sec, 00=.5 sec, factory set to 5 sec) ..........
* Relay activation code: one or two digits (factory set to 36) .....................................
Security code (factory set to 845464) .......................................................................
Maximum call time : 0-99 sec (00=disabled, factory set to 40 sec) ...........................
Disable tenant keyless entry ....................................................................................
Enable tenant keyless entry (factory setting) .........................................................
Disable ring-thru mode (factory setting) ..................................................................
Enable ring-thru mode ..............................................................................................
Enable 911 and 311 calling from entrance phones (factory setting) ........................
Disable 911 and 311 calling from entrance phones ..................................................
1 second pause anywhere in the dialing string ........................................................
Access auxiliary line .................................................................................................
Clear all phone numbers and keyless entry codes from memory and
set all programming features back to factory settings ...............................................
* The relay may be activated with a single digit. When a single digit (0-9) relay activation code is programmed, the activation Touch
Tone must be held for a minimum of 150 milliseconds.
Notes: Each pause uses a single digit. To clear a memory location, enter only the location (no digits). A valid programming entry
will be indicated by a double beep. An invalid entry will be indicated with three beeps.
Enter Digits
- then -
phone number
+
phone number + #
,
+ entry code +
,,
,
#
#
,
+ entry code
+
#
,
+ entry code
+
#
,
+ entry code
+
(no digits)
+
1-3 digit
+
2 digits (00 - 99)
+
2 digits (00 - 99)
+
2 digits (00 - 99)
+
2 digits (00 - 99)
+
1 or 2 digits (0 - 99)
+
,
6 digits (no # or
)
+
2 digits (00 - 99)
+
,
1
,
2
,
3
,
4
,
5
,
6
,
8
,
9
(CAUTION: Erases ALL programming!)
###
Memory
Location
#001-250
#001-250
#001-250
#000
#251-255
#001-255
##2
##31
##32
##33
##34
##4
##5
##6
7