Request To Exit; Data Logging - Viking K-1900-8 Technical Practice

Apartment/office entry controller
Hide thumbs Also See for K-1900-8:
Table of Contents

Advertisement

D. Ring-Thru Mode
If the Ring-Thru mode is selected (see Programming section J), incoming calls are allowed to ring through the C-4000
to Entry Phone 1. If that door phone has an auto-answer feature, this will allow the user to "monitor" that entry way.
The C-4000 is still watching for the security code and will seize the line if a valid code is detected. In this manner, the
C-4000 may still be remotely programmed. In this mode the relay activation code may also be used to buzz in approach-
ing guests. If the Ring-Thru mode is turned off, the C-4000 will answer all inbound calls and watch for the security code
for remote programming. Note: To utilize the Ring-Thru mode with a K-1700-3 entry phone, DIP switch 5 on the K-1700-
3 must be in the ON position (Fax Back Document 157).
E. AUX Line
Any tenant phone number that is programmed with a leading "
tions instead of the "C.O." connections. The ability to dial out on one of two lines provides additional flexibility to some
unusual installations. For example: Some tenants do not have C.O. phone service, so a Viking C-3000 is used to ring
those tenants phones, or some tenants phones are on PABX extensions, so the "AUX" line can be wired to that PABX
for extension dialing. Note: When using a C-3000 with the C-4000, the relay activation code in the C-3000 should be
"disabled" by accessing the programming mode of the C-3000 and dialing "##4".
F. Request to Exit
If a "Push to Open" button, push bar switch, key switch, motion sensor, etc. provides a momentary contact closure to
the Request to Exit screw terminals, the door strike relay will activate. This can be used for a receptionist to allow
entry for visible guests, activate a gate for exiting tenants, provide key access for postal service, etc.
G. Data Logging
Each time there is an entry point event, the C-4000 will transmit 1200 baud ASCII data out of its LOG BUS screw ter-
minals. An example of 5 different entry events is shown below. The C-4000 outputs entry event data in real time, but
does not time stamp.
Examples:
Valid Card Entry ...........................
Valid Card Entry ...........................
Non-Valid Keyless Attempt .........
Valid Keyless Entry ......................
A guest was granted entry by .....
tenant in memory location 007
Entry Point ID Number
If the entry attempt Valid (V)
or Not Valid (N)
H. Entry Logger Software
Visit www.vikingelectronics.com to download free ENTRY LOGGER software. The software provides transaction log-
ging for the ES-1 and C-4000 Entry Controller systems. Compatible with any Windows based PC running Windows 98
or higher, the software adds time and date stamps to each transaction, and allows user printing, record saving, and
complete search capabilities.
P
r
o
d
u
c
t
S
u
p
p
o
r
P
r
o
d
u
c
t
S
u
p
p
o
r
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or
subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate
such changes.
Fax Back Doc 164
10
Simulated LOG BUS Output
1
V
3
V
N
1
V
2
V
4
t
L
i
n
e
.
.
.
7
1
5
.
3
8
6
.
t
L
i
n
e
.
.
.
7
1
5
.
3
8
6
.
9" will be dialed out the "AUX" screw terminal connec-
,
255
12345
132
06336
KLS
8132
KLS
708132
GST
007
Card number from Wiegand device or keyless code entered
(keypad) or tenant memory location number if a guest called
Facility Code from Wiegand device or (KLS) for keyless code,
or (GST) if a guest called a tenant
8
6
6
6
8
6
6
6
Printed in the U.S.A.
F
a
x
B
a
c
k
L
i
n
e
.
.
.
F
a
x
B
a
c
k
L
i
n
e
.
.
.
7
1
5
.
3
8
6
.
4
3
4
5
7
1
5
.
3
8
6
.
4
3
4
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C-4000Hid-1Hid-2K-1700-3

Table of Contents