Viking K-1900-8 Technical Practice page 5

Apartment/office entry controller
Hide thumbs Also See for K-1900-8:
Table of Contents

Advertisement

B. Optional LOG BUS Wiring
The C-4000 transmits 1200 baud ASCII data from the
LOG BUS screw terminals. Log Bus data is sent each
time there is an entry point event, and includes: an
entry point ID number, if the entry was valid or non-
valid, the facility code, and the card number (or key-
pad entry code).
Pin 2
(Receive Data)
If the RS-232 input of a PC, printer, etc. is capable of receiving TTL level
RS-232 signals, then the LOG BUS can be wired directly into the RS-232
"Receive Data" and "Signal Ground" pins to receive ASCII data. Windows
"Hyper-Terminal" can be used to receive the data on a PC. Use the set-
tings in the chart at the right:
C. Optional PC Programming Wiring
Programming the C-4000 can be done with a Touch Tone phone or by using a PC. If using PC programming, use a
serial port connection as shown below and visit www.vikingelectronics.com to download free C-4000 programming
software. Compatible with any Windows based PC running Windows 98 or higher, the software allows programming of
all C-4000 parameters using the computer.
Note: After PC programming is accomplished, it is recommended to not use Touch Tone programming to make
changes, as these changes will not show in the PC programming data base. If Touch Tone programming is used to
make changes, be sure to make those same changes in the PC programming data base to keep it accurate.
VIKING
APARTMENT OR OFFICE
POWER
13.8 VAC
DOOR STRIKE RELAYS
PROGRAM
PHONE
LED1
C
N.O. COM N.C.
N.O. COM N.C.
DOOR STRIKE 1
DOOR STRIKE 2
PROGRAM
PHONE
C.O. LINE
AUX
ENTRY
INPUT
LINE
PHONE 1
DB-9
(not included)
Pin 5
(Signal Ground)
H
Brown (Receive Data)
L
Yellow (Signal Ground)
©
MODEL C-4000
VIKING
ELECTRONICS
HUDSON, WI 54016
ENTRY CONTROLLER
WIEGAND INPUTS
N.O. COM N.C.
N.O. COM N.C.
BLK RED GRN WHT
BLK RED GRN WHT
BLK RED GRN WHT
BLK RED GRN WHT
DOOR STRIKE 3
DOOR STRIKE 4
ENTRY 1
ENTRY 2
ENTRY 3
ENTRY 4
RS-232 PORT
ENTRY
ENTRY
ENTRY
REX
REX
REX
REX
H
L
PHONE 2
PHONE 3
PHONE 4
1
2
3
4
LOG BUS
VIKING
©
VIKING
ELECTRONICS
HUDSON, WI 54016
APARTMENT OR OFFICE
ENTRY CONTROLLER
POWER
13.8 VAC
DOOR STRIKE RELAYS
PROGRAM
PHONE
LED1
C
N.O. COM N.C.
N.O. COM N.C.
N.O. COM N.C.
N.O. COM N.C.
BLK RED GRN WHT
DOOR STRIKE 1
DOOR STRIKE 2
DOOR STRIKE 3
DOOR STRIKE 4
ENTRY 1
PROGRAM
PHONE
C.O. LINE
AUX
ENTRY
ENTRY
ENTRY
ENTRY
REX
INPUT
LINE
PHONE 1
PHONE 2
PHONE 3
PHONE 4
1
1610m (5280 ft - 1 mile) maximum run length using 24 gauge wire
Communication Software Configuration
Com
Baud Rate
Data Bits
Stop Bits
Parity
Flow Control
* IMPORTANT: Viking Electronics will NOT support com-
puter software or hardware problems. If you experience
these problems, research your hardware/software instruc-
tion manuals or contact the manufacturer's technical sup-
port department.
MODEL C-4000
WIEGAND INPUTS
BLK RED GRN WHT
BLK RED GRN WHT
BLK RED GRN WHT
ENTRY 2
ENTRY 3
ENTRY 4
RS-232 PORT
REX
REX
REX
H
L
2
3
4
LOG BUS
Your serial port (1-4)
1200
8
1
none
none