Side Channel Fan Starter; Motor Protection - Nederman S Series User Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Part no.
Area
(A)
[m ]
Cartridge filter
43130001
2,38
43130100
2,38
43130500
1,56
*
According to EN 60335-2-69/EN 1822
** Replace the cartridge filter after it has been washed twice.
Filter socks
40119422
1,1

3.3 Side channel fan starter

See
Figure
3.
A Start button
B
Reset button (motor protection)

3.3.1 Motor protection

See
Figure
4,
Section 5.2 Reset motor protection
The motor protection turns the fan off if the motor temperature reaches 110°C (230°F).
NOTE!
3kW motors do not have a ball bearing temperature sensor.
S - Vacuum Cleaners
Diameter
Length
Material
(D) [mm]
(L)
[mm]
264
220
Cellulose
264
220
Cellulose
264
220
Cellulose/Fiberglass/Cel-
lulose 3 layers
75x12
430
Polyester (PTFE coated)
and
M
Chapter 7
Troubleshooting.
Filter
Max.temp
Wash-
*
[°C]
class
able
M
70
N/A
M
70
N/A
H13
70
N/A
150
N/A
EN
**
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

690s680s4246807242469000

Table of Contents