TROUBLESHOOTING

WARNING: Before beginning work, shut off the power supply to avoid electrical shock.
PROBLEM
Fan does not move.
Noisy operation.
Excessive wobbling.
Fan operates but
lights fail.
POSSIBLE CAUSE
1. Reverse switch not engaged.
2. Power is off or fuse is blown.
3. Faulty wire connection.
1. Blades are loose.
2. Cracked blade.
3. Full range dimmer switch.
4. Fan is new.
1. Blades are loose.
2. Unbalanced blades.
3. Fan not securely mounted.
4. Fan too close to vaulted ceiling.
5. Set screw(s) on motor housing yoke
is (are) not tightened properly.
6. Set screw on hanging ball is not
tightened properly.
1. Bulb not installed correctly.
2. Wires in canopy not wired properly.
3. Wall switch to light is off.
4. Wires in light kit fitter not wired
correctly.
CORRECTIVE ACTION
1. Push switch firmly either left or
right.
2. Turn power on or check fuse.
3. Turn power off. Loosen canopy
and check all connections.
1. Tighten all blade screws.
2. Replace blade.
3. Replace with an approved speed
control device.
4. Allow fan a "break in" period of a
few days, especially when running
the fan at Medium and High
speeds.
1. Tighten all blade screws.
2. Switch one blade with a blade
from the opposite side.
3. Turn power off. Carefully loosen
canopy and verify that mounting
bracket is secure.
4. Use a longer downrod or move fan
to another location.
5. Tighten yoke set screw(s)
securely.
6. Carefully loosen and lower canopy
and verify that set screw on
hanging ball is tightened securely.
1. Re-install bulb.
2. Check wires in canopy and, if
necessary, re-wire according to
instructions on pages 10 - 12.
3. Make sure that wall switch to light
is on.
4. Check that molex connections in
light kit fitter are connected
properly according to instructions
on page 14.