Servicing; Guarantee Regulations; Recognising And Repairing Of Mistakes - Profi-pumpe DIE LIEBENDEN 200-1 Operating Instructions Manual

Solar fountains
Table of Contents

Advertisement

Available languages

Available languages

9. SERVICING

If after some time the pump starts losing power or stops working, please clean up sediment in the pump shell or filter
cribs. Kindly note the pump can be opened by pressing down at the bottom of the filter housing. To clear the impeller,
open the pump housing at the front by sliding up the front plastic cover.
The solar module should only be
cleaned with soft tissue or propriety
glass cleaning solution.
1. Pump case
2. Impeller cover
3. Impeller
4. Pump
5. Filter

10. GUARANTEE REGULATIONS

For all manufacturer defects and material defects we grant the legal guarantee time (new and unused product). In
such cases
we take over the exchange or the repair of the pump. Forwarding expenses are not carried by us.
The guarantee is not valid with:
l Material wear (sealing rings, impeller wheels, impeller chambers)
l Unjustified interventions or changes in the pump
l Damages by selffault
l Improper servicing and improper use
l DRY RUN (Also partially!) of the pump
Moreover, we give no damage compensation for secondary damages!

11. RECOGNISING AND REPAIRING OF MISTAKES

Problem
Pump will not turn on
Pump runs but no water
is encouraged
Pull off filter cover as shown
Open impeller cover, then
impeller can be easily removed
Possible cause
No sunlight
Low charge level of the battery
Pump connector is not connected correctly
Defective pump / solar panel broken
Pump impeller and filter housing polluted
The flow controller to the pump is closed
Pump has sucked air
Coarsining or fountain nozzles dirty
Remove filter and rinse in water
Rinse all parts thoroughly in water
Solution
The orientation of the solar panels up to
the sun
See item 6 and 7 (Note)
See item 3.4
Replace pump or solar panel
Disassemble and clean in accordance
with point 9, the pump and the housing (by
means of water and a soft brush)
Open the flow regulator on the pump
Turn off the pump briefly and then back on
(restarting) Attention! Avoid dry running
Disassemble and clean the tube and the
fountain nozzle
English 5

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Sp02108Sp02106Sp02107

Table of Contents