Connections on the heating water side

Connect all pipework with detachable fittings.
Seal any connections that are not required with red
brass caps.
Adjust the temperature controller and high limit
safety cut-out so that the DHW temperature in the
DHW cylinder does not exceed 95 °C.
!
Please note
The internal indirect coil is installed with gas-
kets.
Temperatures > 150 °C at the connections will
damage the gaskets.
Maintain a safe distance when soldering and
welding.
Realigning the connector will damage the gas-
kets.
Permissible heating water flow temperature
Solar side
Heating water side
Permissible operating pressure
Solar side
Heating water side
DHW side
Test pressure
Solar side
Heating water side
DHW side
Permissible DHW temperature
Heating DHW with solar collectors
Via the lower indirect coil and heat supply for reheating
or heating the DHW with a boiler via the upper internal
indirect coil (parallel operation)
Installation sequence
160 °C
160 °C
10 bar
1 MPa
10 bar
1 MPa
10 bar
1 MPa
16 bar
1.6 MPa
16 bar
1.6 MPa
16 bar
1.6 MPa
95 °C