PARAMETERISATION
Relay 1= Heat pump
r 1 : w a e r m e p u m
p e z w : a i n p n : a i
n
r 1 v e r z o e . 0 0 0 s w
p s c h w . + 0 0 0 w
Heat pump: If the heat pump control behaviour is selected, two additional
parameters are available.
R1 Switch-off delay: Relay switches off after the set time (0 to 999s) has elapsed
after the set threshold value has been exceeded.
WP Threshold: The threshold can be set between -99999W and +99999W.
Relay 1
R 1 N = 0 0 0 T D = 0 0 M P
= 0 0 0 0 W T H = 0 0 0 M
R1 is the designation of the relay. N is the value of how often a
relay should be activated per day, adjustable between 0 and 999.
0 means the relay is deactivated and is therefore not taken into account. If the
relay is to be activated as often as possible, 999 can be selected.
20
w w w . s m a r t f o x . at