Carrier KSACN0901AAA Owner's Manual page 35

Wired remote controller 7 day programmable thermostat ductless systems
Table of Contents

Advertisement

FOLLOW ME Mode Temperature Compensation
1. When the air conditioning unit is OFF and in QUERY mode, press the UP or DOWN arrow to select tF.
The compensation temperature Range: 23°F ~ 41°F (-5°C~5°C).
2. Press CONFIRM to enter the temperature compensation value.
3. Press the UP or DOWN arrow to select the temperature compensation value.
4. Press CONFIRM to set
Mode Customization
This setting allows the configuration of the wired controller customizing the modes available for the
user as CH Heat Pump, CC Cooling Only, HH Heating Only or NA No AUTO Mode.
1. When the air conditioning unit is OFF and in query mode, press UP or DOWN arrow to select TYPE.
2. Press CONFIRM to enter TYPE, press UP or DOWN arrow to select the type (see Fig. 82).
3. Press CONFIRM.
OM-KSACN0901-02
Fig. 80 — Up or Down Arrows - Select Confirm
compensation temperature.
Fig. 81 — Up or Down Arrows - Select Type
CH: HEAT PUMP
CC: COOLING ONLY
Fig. 82 — Press CONFIRM
Specifications subject to change without notice.
HH: HEATING ONLY
NA: No AUTO MODE
35