Operating instruccions Peristaltic Pumps
CIP cleaning
- In the event of CIP cleaning, it is necessary to obtain information
- Cleaning should be undertaken at the recommended maximum
Direction of rotation/flow direction
Possible consequence: material damage, destruction of the unit.
- The pump's direction of rotation in relation to the desired flow di-
Disconnect the pump from the mains
Possible consequence: personal injury.
- Work may only be carried out on the pump after it has previously
Environmental influences
Possible consequence: material damage up to destruction of the unit.
- The device is suitable for outdoor operation once it is covered and
- Take suitable measures to protect the device from environmental
- UV rays
- moisture
- frost, etc.
DSM Series
tion of a possible (although most unlikely) incorporation of particles
from the tube into the product being pumped. This can be achieved
by means of filtration, a tube rupture alarm or other means suitable
for the respective process
from the manufacturer about correct installation of the pump (a
special installation is required) as well as regarding the compati-
bility of the cleaning agents with the tubes and the hydraulic con-
nections.
temperature.
rection must be checked prior to every start.
been switched off and disconnected from the mains.
protected from rain and direct sunlight. Ambient conditions must
also be respected, see Section 6.2 & 6.3.
influences such as