3.
Remove tube.
4.
Position the new tube.
5.
Lower the lever.
6.
Mount the pipes from both discharge and suction sides.
7.
Open all of the valves.
8.4.
Replacement of electric motor
For repair or replacement of the electric motor they could be disassembled from the
pump housing. The pump is stable on its baseplate and will not fall over when the electric
motor is disassembled.
No support set is necessary.
8.5.
Addition of leak detection sensor
Standard DSM pump housing is not prepared for addition of leak
detection sensor.
The alternative is to order the DSM pump assembled onto a co-
llector with its own leakage detector