5. Installation and Discovery & Enrollment Process

Select Mounting Location

The installation of the WPIR-EXT requires a flat and secure mounting surface for the detector to perform correctly.
The protected area must be free from obstacles like walls, fences, trees, ditches, and other microwave detectors, as
well as systems of anti-intrusion surveillance.
The back metal bracket enables WPIR-EXT installation on a level wall or pole.
Choose a location most likely to intercept an intruder according to the detection pattern on page 6.
Avoid the following installation locations:
Facing direct sunlight
Facing areas subject to rapid temperature changes
Wall angle of more than 10º from perpendicular line
Mounting at more than 10º Deviation from horizontal line
Facing metal doors
Do not install near direct source of heat or air gust
Clear all physical obstacles from the detection area (for example
Plants, laundry, etc.)
Clear all light reflecting surfaces from the detection area, as well as
water puddles
Avoid installation on the following types of ground:
Thick vegetation, Grass (un-mown), Water, Sand, and Metal.
NOTE:
Recommended installation height is 1.2m.
If there is a risk of the protected area may contain tall pets (over 60cm), install the detector at a height of
1.5m.
The Double Quad high quality sensor detects motion crossing the beam; it is less sensitive detecting motion
towards the detector.
The WPIR-EXT performs best when provided with a constant and stable environment.
To ensure suitable operation of the WPIR-EXT type of ground should be one of the following: Asphalt
concrete, Cement, Soil, Clay, Gravel, or Grass (mown).