4 Power Connector and LEDs

4 Power Connector and LEDs

4.1 Power Connector

+24V
RST
GND
PE
Figure 3: Power plug
The VisionBox does not connect ground and the housing with each other to avoid ground loops with other
connected devices. It is good practice to connect them at a single point in the facility.
The RST terminal can be pulled to GND to reset the VisionBox during operation. A falling edge will trigger
the reset. Leaving the signal floating is the default mode for normal operation.
Phoenix Contact plug component: MC 1,5/4-STF-3,5 (order no. 1847071)

4.2 System LEDs

The computer has four main system LEDs. These LEDs are dual color (bicolor) types. The functionality of
the LED A, B and C can be changed by software.
Figure 4: Status LEDs
LED
ON
A
B
C
IMAGO Technologies GmbH
Strassheimer Str. 45; 61169 Friedberg - Germany; Tel. +49 6031-6842611
info@imago-technologies.com;
Pin
Function
+24V
24 V power supply
RST
Reset input, low active
GND
Ground (power / signals)
PE
Earth / housing connection
Table 3: Power connector
Color
Green
Power On
Green
USB recovery mode
blinking
Red
FPGA configuration error
Orange
System shutdown or reset
Green
User LED 0
Red
User LED 1
Green
User LED 2
Red
User LED 3
Green
User LED 4
Red
User LED 5
Table 4: System LED values