  • Page 1 40-850/852 User Manual PXI MEMS Fiber Optic Multiplexer Module pickeringtest.com Issue 5.5 August 2022...
  • Page 2 © COPYRIGHT (2022) PICKERING INTERFACES. ALL RIGHTS RESERVED. No part of this publication may be reproduced, transmitted, transcribed, translated or stored in any form, or by any means without the written permission of Pickering Interfaces. Technical details contained within this publication are subject to change without notice.
  • Page 3 Pickering Interfaces strives to fulfil all relevant environmental laws and regulations and reduce wastes and releases to the environment. Pickering Interfaces aims to design and operate products in a way that protects the environment and the health and safety of its employees, customers and the public. Pickering Interfaces endeavours to develop and manufacture products that can be produced, distributed, used and recycled, or disposed of, in a safe and environmentally friendly manner.
  • Page 4: Product Safety

    LASER PRODUCT This product is capable of switching laser optical signals. STATIC SENSITIVE To indicate that static sensitive devices are present and handling precautions should be followed. REED RELAY MODULE 40-110/115/120/125 MEMS FIBER OPTIC MULTIPLEXER MODULE 40-850/852 Page (IV) Page (IV)
  • Page 5: Table Of Contents

    Pre Operation Checks ............3.1 Hardware Installation ............3.2 Software Installation .............3.2 Testing Operation ..............3.3 Section 4 Programming Guide ..............4.1 Programming Options For Pickering PXI Modules ....4.1 Module Architecture ..............4.2 Programming The Module ............4.3 Section 5 Connector Information ..............5.1 Section 6 Trouble Shooting .................6.1 Section 7 Maintenance Information ............7.1...
  • Page 6 THIS PAGE INTENTIONALLY BLANK MEMS FIBER OPTIC MULTIPLEXER MODULE 40-850/852 Page (VI)
  • Page 7: Warnings And Cautions

    Unused slots in the PXI/LXI chassis are populated with blanking plates to prevent access to user I/O signals that may be present. Blanking panels are available to order from Pickering in a variety of slot widths. If the product is not used in this manner for example by using an extender card then additional care must be taken to avoid contact with exposed signals.
  • Page 8 I/O ports. • For suitably equipped products in the event of an emergency press the red “emergency stop” button situated on the front of the unit. MEMS FIBER OPTIC MULTIPLEXER MODULE 40-850/852 REED RELAY MODULE 40-110/115/120/125 Page (VIII)
  • Page 9 Optic Multiplexer y Supported by PXI or LXI Chassis y 3 Year Warranty Pickering PXI MEMS Fiber Optic multiplexer modules are available Ch 1 in 8:1 or 4:1 formats with a choice of 5 different connector styles to Ch 2...
  • Page 10 Optical Input Power: 300 mW Max Other Connector Styles Thermal Stability: 0.2 dB Max Pickering can manufacture Fiber Optic Switch modules (-10 to 75 °C insertion loss variation) with other connector styles, please contact sales office for Expected Life: >>10 operations further information.
  • Page 11 40-852-218-M50 Multi-Mode 50/125 40-852-318-M50 Multi-Mode 50/125 40-852-418-M50 Multi-Mode 50/125 40-852-518-M50 FC/APC Multi-Mode 62.5/125 40-852-018-M62.5 FC/PC Multi-Mode 62.5/125 40-852-118-M62.5 SC/PC Multi-Mode 62.5/125 40-852-218-M62.5 Multi-Mode 62.5/125 40-852-318-M62.5 Multi-Mode 62.5/125 40-852-418-M62.5 Multi-Mode 62.5/125 40-852-518-M62.5 pickeringtest.com MEMS FIBER OPTIC MULTIPLEXER MODULE 40-850/852 Page 1.3...
  • Page 12 We provide a full range of supporting cable and connector solutions for all our switching products—20 connector families with 1200+ products. We offer everything from simple mating connectors to complex cables assemblies and terminal blocks. All assemblies are manufactured by Pickering and are guaranteed to mechanically and electrically mate to our modules. Connectors & Backshells...
  • Page 13 MEMS Fiber Optic MUX, 40-850/852 Programming Pickering provide kernel, IVI and VISA (NI & Keysight) drivers which are compatible with all Microsoft supported versions of Windows and popular older versions. For a list of all supporting operating systems, please see: pickeringtest.com/os...
  • Page 14 SECTION 1 - TECHNICAL SPECIFICATION pickering THIS PAGE INTENTIONALLY BLANK MEMS FIBER OPTIC MULTIPLEXER MODULE 40-850/852 Page 1.6...
  • Page 15: Functional Description

    FUNCTIONAL DESCRIPTION Functional block diagrams for the 40-850 and 40-852 are provided in Figures 2.1 and 2.2. The Fiber Optic Multiplexer Module is powered by a +5V input via Compact PCI connector J1. The module comprises a Fiber Optic multiplexer (4:1 for the 40-850 and 8:1 for the 40-852) which connects an optical channel by redirecting the optical signal received at the common input into a selected output fibre.
  • Page 16 SECTION 2 - TECHNICAL DESCRIPTION pickering THIS PAGE INTENTIONALLY BLANK MEMS FIBER OPTIC MULTIPLEXER MODULE 40-850/852 Page 2.2...
  • Page 17: Installation

    Modular products require installation in a suitable PXI/LXI chassis. The module is designed for indoor use only. PREOPERATION CHECKS (UNPACKING) 1. Check the module for transport damage and report any damage immediately to Pickering Interfaces. Do not attempt to install the product if any damage is evident.
  • Page 18: Hardware Installation

    For a system comprising more than one chassis, turn ON the last chassis in the system followed by the penultimate, etc, and finally turn ON the external controller or chassis containing the system controller. 9. For Pickering Interfaces modular LXI installation there is no requirement to use any particular power up sequence.
  • Page 19: Testing Operation

    Figure 3.2 - General Soft Front Panel Icon A selector panel will appear, listing all installed Pickering PCI, PXI or LXI switch cards and resistor cards. Click on the card you wish to control, and a graphical control panel is presented allowing operation of the card.
  • Page 20 SECTION 3 - INSTALLATION pickering THIS PAGE INTENTIONALLY BLANK MEMS FIBER OPTIC MULTIPLEXER MODULE 40-850/852 Page 3.4...
  • Page 21: Programming Guide

    SECTION 4 - PROGRAMMING GUIDE PROGRAMMING OPTIONS FOR PICKERING INTERFACES PXI MODULES For information on the installation and use of drivers and the programming of Pickering’s products in various software environments, please refer to the Software User Manual. This is available as a download from: https://www.pickeringtest.com/support/software-drivers-and-downloads...
  • Page 22: Module Architecture

    MODULE ARCHITECTURE The 40-850/852 modules utilise opical MEMS relays. In the default state Channel 1 is selected. Energising the appropriate MEMS switch creates a signal path between the Common and another Channel terminal. The module’s switching architectures are shown in their default state in the diagrams below:...
  • Page 23: Programming The Module

    PROGRAMMING THE MODULE Here are examples of using the drivers with the 40-850-014 (4 Channel MUX) module. The 40-852-018 (8 Channel MUX) module operates in the similar way but has a different number of bits in the sub-unit. Using PILPXI...
  • Page 24 SECTION 4 - PROGRAMMING GUIDE pickering THIS PAGE INTENTIONALLY BLANK MEMS FIBER OPTIC MULTIPLEXER MODULE 40-850/852 Page 4.4...
  • Page 25 Channel 1 Common Figure 5.1 provides pin outs for the Fiber Optic Multiplexer Modules in the 40-850 Single 4:1 MUX range, Figure 5.2 Channel 2 provides pin outs for the Fiber Optic Multiplexer Modules in the 40-852 Single 8:1 MUX range.
  • Page 26 Block Diagram of an 8 Channel Fiber Optic Multiplexer Reset State pickering pickering pickering pickering pickering Set State 40-852-018/118 40-852-218 40-852-318 40-852-418 40-852-518 Figure 5.2 - Single 8:1 Fiber Optic Multiplexer Module 40-852: Connector Positions MEMS FIBER OPTIC MULTIPLEXER MODULE 40-850/852 Page 5.2...
  • Page 27: Trouble Shooting

    PCI configuration, highlighting any potential configuration problems. Specific details of all installed Pickering switch cards are included. All the installed Pickering switch cards should be listed in the “Pilpxi information” section - if one or more cards is missing it may be possible to determine the reason by referring to the PCI configuration dump contained in the report, but interpretation of this information is far from straightforward, and the best course is to contact Pickering support: support@pickeringtest.com, if possible...
  • Page 28 SECTION 6 - TROUBLE SHOOTING pickering THIS PAGE INTENTIONALLY BLANK MEMS FIBER OPTIC MULTIPLEXER MODULE 40-850/852 Page 6.2...
  • Page 29: Maintenance Information

    For PXI modules which are supported in one of Pickering Interfaces’ Modular LXI Chassis (such as the 60-102B and 60-103B) no module software update is required. If the module was introduced after the LXI chassis was manufactured the module may not be recognized, in this case the chassis firmware may need upgrading.
  • Page 30 SECTION 7 - MAINTENANCE INFORMATION pickering Table 7.1 - Fiber Optic Multiplexer Module 40-850: Relay Numbering Signal Path 40-850 (with relay energised) Relay No. Com to Channel 1 Com to Channel 2 Com to Channel 3 Com to Channel 4 Table 7.2 - Fiber Optic Multiplexer Module 40-852: Relay Numbering...