Download Print this page

Technics RS-TR474 Service Manual page 19

Hide thumbs Also See for RS-TR474:

Advertisement

| RS-TR4;
HWRITING TO EEPROM
__.
Since it hardly breaks down, there will scarcely occur such a trouble as to require replacement.
Measurement Condition
¢ Recording-level control; Maximum
* Make sure heads are clean
e Reverse-mode selector switch; =
;
¢ Judgeable room temperature 20+5°C (68+9°F)
¢ Tape-to-tape recording-speed switch; Off
:
¢ Dolby NR switch; Off
¢ ATC switch; Off
Measuring instrument
e EVM (Electronic Voltmeter)
¢ ATT (Attenuator)
¢ Oscilloscope
¢ Resistor (600Q)
° AF oscillator
:
;
NOTE:
Before adjustment, be sure to set the AF oscillator output level to OdB (1kHz): 1V
Test tape
es
¢ Playback gain adjustment (315Hz, 0dB); QZZCFM
...
* Overall gain adjustment and Overall} frequency response
Normal reference blank tape; QZZCRA
CrO, reference blank tape; QZZCRX1
Metal reference blank tape; QZZCRZ5
NOTE: Step 1 to step 7 only has to be done after exchange of the EEPROM.
Short the Test Mode terminals with a shorting clip.
Step 1
OPERATION PC.B.
Step
2
While
holding
down
the STOP
button on DECK2,
press the POWER
Y
Pp
:
switch to ON.
All FL display segments
except for the four-digit counter on DECK2
Short Clip
will start blinking to indicate that the deck has entered Write mode.
At this point the four-digit counter will indicate "OQ-k".
Step 3
Notes:
* The test mode terminals
on main P.C.B. should be
shorted with a short clip
as shown above figure.
« After the adjustment
items disconnect the
short clip.

Advertisement

loading