schmersal AZM400Z-ST-1P2P-T Instructions For Operation And Use

schmersal AZM400Z-ST-1P2P-T Instructions For Operation And Use

Solenoid interlock
Hide thumbs Also See for AZM400Z-ST-1P2P-T:

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AZM400Z-ST-1P2P-T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal AZM400Z-ST-1P2P-T

  • Page 1: Table Of Contents

    INSTRUCTIONS FOR OPERATION AND ASSEMBLY Solenoid interlock AZM400Z-ST-1P2P-T Table of Contents 1 About this document 1.1 Function 1.2 Target group of the operating instructions: authorised qualified personnel 1.3 Explanation of the symbols used 1.4 Appropriate use 1.5 General safety instructions 1.6 Warning about misuse...
  • Page 2: About This Document

    Warning:Failure to comply with this warning notice could lead to physical injury and/or damage to the machine. 1.4 Appropriate use The Schmersal range of products is not intended for private consumers. The products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine.
  • Page 3: General Safety Instructions

    The user must observe the safety instructions in this operating instructions manual, the country specific installation standards as well as all prevailing safety regulations and accident prevention rules. Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: products.schmersal.com.
  • Page 4: Special Versions

    1 Connector plug M12, 8-pin 2 Connector plug M12, 8-pin / 5-pin without Standard coding Individual coding Individual coding, multiple teaching 1P2P 1 serial diagnostic output and 2 p-type safety outputs (only for ST) 2P2P 2 serial diagnostic output and 2 p-type safety outputs (only for ST2) without Manual release Emergency exit...
  • Page 5: Technical Data

    The safety switchgears are classified according to EN ISO 14119 as type 4 interlocking devices. Designs with individual coding are classified as highly coded. The first of the two safety functions is the safe shut-down of both safety outputs when unlocking or opening the guard system and making sure that the switched-off position is maintained when the guard system is open or unlocked (locking function).
  • Page 6 Housing material Light alloy die-casting Reaction time, switching off safety outputs via actuator, maximum 100 ms Gross weight 846 g General data - Features Solenoid interlock monitored Emergency exit Short circuit detection Cross-circuit detection Safety functions Integral system diagnostics, status Number of diagnostic signals Number of safety contacts Safety classification...
  • Page 7 Mechanical data Interlocking principle bistable Mechanical life, minimum 1,000,000 Operations Note (Mechanical life) Which have a lateral force Ftrans = 100 N: 100.000 operations Allowed distance interlock to actuator, minimum 1 mm Allowed distance interlock to actuator, maximum 7 mm Angular misalignment between solenoid interlock and actuator, 2 °...
  • Page 8 Restistance to shock 30 g / 11 ms Protection class Permissible installation altitude above sea level, maximum 2,000 m Ambient conditions - Insulation values Rated insulation voltage U 32 VDC Rated impulse withstand voltage U 0.8 kV Overvoltage category Degree of pollution Electrical data Operating voltage 24 VDC -15 % / +10 % (stabilised PELV power supply)
  • Page 9 Permissible residual drive current 1.5 mA Electrical data - Safety digital outputs Designation, Safety outputs Y1 and Y2 Design of control elements short-circuit proof, p-type Voltage drop U , maximum Leakage current I , maximum 0.5 mA Voltage, Utilisation category DC-12 24 VDC Current, Utilisation category DC-12 0.25 A...
  • Page 10: Mounting

    This device complies with the nerve stimulation limits (ISED CNR-102) when operated at a minimum distance of 100 In the event of changes or modifications that have not been expressly approved by K.A. Schmersal GmbH & Co. KG, the user's authorisation to use the device may become ineffective.
  • Page 11 Please observe the remarks of the standards EN ISO 12100, EN ISO 14119 and EN ISO 14120. Any position is possible. The accumulation of fine-grained dirt in the bolt area must be avoided. In such a case it is therefore not advised to have vertical mounting, where the bolt goes upwards from below. For the correct fixing of the solenoid interlock, the device is provided with two mounting holes for M6-screws.
  • Page 12   The approach direction must only be from the X and Y directions. The maximum distance of 7 mm between the actuator and the solenoid interlock must be maintained so that the stipulated holding force and the safe clamping function is achieved according to SIL 3. The construction of the guard door is to be designed so that it is not possible to move the guard system with the actuator on the Z axis so far that the distance between the interlock and the actuator is greater than 7 mm.
  • Page 13: Manual Release

        3.2 Manual release For the machine set-up, the solenoid interlock can be unlocked in a de-energised condition. Turning the triangle of the manual release using the triangular key to the position releases the solenoid interlock. The normal locking function is only restored after the manual release has been returned to its original position Triangular key TK-M5 (101100887) available as accessory.
  • Page 14: Emergency Exit -T

    The electrical manual release can be achieved with an additional auxiliary power supply. The auxiliary power supply unit H1 is for this purpose. The AZM400 should only be supplied with the auxiliary power supply, this is so the locking bolt can be released independently of the control inputs.
  • Page 15: Dimensions

    When using 40 mm aluminium profile, the optimum mounting set MS-AZM400 can be used. This consists of two mounting plates including four bolt and four nuts. 3.6 Dimensions All measurements in mm. 15-30...
  • Page 16 AZM400Z-ST AZM400Z-ST2 AZM400 with emergency exit 16-30...
  • Page 17: Actuator And Accessories

    AZM400Z-ST..-T AZM400Z-ST2..-T         Manual release with cover Emergency Exit Locking bolt (extended) Connector plug M12, 8-pole Connector plug M12, 5-pole RFID Sensor 3.7 Actuator and accessories Actuator AZM400-B1 (not included in delivery) 17-30...
  • Page 18 Mounting plate, part of the mounting set MS-AZM400 (available as accessory) Lockout tag SZ400 (available as accessory) For detailed information and assembly instructions, see operating instructions SZ400 18-30...
  • Page 19: Electrical Connection

    Bowden cable release ACC-AZM400-BOW-.M-.M (available as accessory) Observe the additional notes in the operating instructions of the Bowden cable release. 4 Electrical connection 4.1 General information for electrical connection 19-30...
  • Page 20: Control Options In The Normal Operating Mode

    The electrical connection may only be carried out by authorised personnel in a de-energised condition. The voltage inputs A1 (and H1 with the AZM400Z-ST2..), and the control inputs E1, E2 and E3 must have a permanent protection against over-voltage. The use of PELV supply units according to EN 60204-1 is recommended. The safety outputs can be integrated into the safety circuit of the control system.
  • Page 21: Requirements For The Connected Safety-Monitoring Module

    100 ms. The safety inputs of the safety-monitoring module must be able to blank a test impulse of < 1 ms. Information for the selection of suitable safety-monitoring modules can be found in the Schmersal catalogues or in the online catalogue on the Internet: products.schmersal.com.
  • Page 22: Wiring Configuration And Connector Accessories

    4.4 Wiring configuration and connector accessories Pin assignment of the version AZM400Z-ST-… Function safety   Pin configuration of Colour codes of the Possible colour code of switchgear the connector M12. 8- Schmersal connector other commercially pole plugs available connector to DIN 47100 plugs    ...
  • Page 23: Wiring Examples

    Function safety   Pin configuration of Colour codes of the Possible colour code of switchgear the connector M12, 5- Schmersal connector other commercially pole plugs available connector to DIN 47100 plugs     according to EN 60947- Functional earth connection 3...
  • Page 24 Key, wiring Connector plug M12, 8-pole Control input 1 Control input 1 Control input 2 Safety output 1 Safety output 2 Diagnostic output Wiring example 2: AZM400Z-ST2 Key, wiring Connector plug M12, 8-pole Connector plug M12, 5-pole Control input 1 Control input 2 Control input 3 Safety output 1...
  • Page 25: Actuator Teaching / Actuator Detection

    5 Actuator teaching / actuator detection Solenoid interlocks with standard coding are ready to use upon delivery. Individually coded solenoid interlocks and actuators will require the following "teach-in" procedure: 1. Switch the solenoid interlock's voltage supply off and back on. 2.
  • Page 26: Diagnostic Outputs

    green (Power) Supply voltage on yellow (Status) Operating condition red (Fault) Error (see table 2: Error messages / flash codes red diagnostic LED) Arrangement of the LEDs     6.3 Diagnostic outputs The short-circuit proof diagnostic output OUT or OUT1 and OUT2 of the ST2 version can be used for central visualisation or control functions, e.g.
  • Page 27 Table 1: Diagnostic information of the solenoid interlock AZM400 System Control Safety  Diagnostic outputs condition  signals outputs Guard ST version ST2 version ST2 version locking green yellow Y1, Y2 OUT1 OUT2 function Door open Unlock and unlocked (bolt retracted) Door closed Unlock Flashes 24 V...
  • Page 28 Teach-in Unlock Flashes procedure slowly actuator started Actuator Unlock Flashes teaching can quickly completed Only I2: Unlock Flashes 24 V 24 V Actuator has been taught (Manipulatio n protection time is running) after 30 min. disabling due to fault see flash code Table 2: Error messages / flash codes red diagnostic LED Flash codes (red) Designation...
  • Page 29: Set-Up And Maintenance

    7 Set-up and maintenance 7.1 Functional testing The safety function of the safety components must be tested. The following conditions must be previously checked and met: 1. Check max. axial misalignment of actuator and solenoid interlock. 2. Check max. angle displacement. 3.
  • Page 30 30-30 Schmersal Canada Ltd., 29 Centennial Road, Unit 1, Orangeville, Ontario L9W 1R1 Canada The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.

Table of Contents