OPERATING PROCEDURES:

7.
STARTING THE GENERATOR ENGINE FOR THE GP6500I:
7.1.1.
Turn the Choke Lever to the "Start" position if the engine is cold.
7.1.2.
Turn the Circuit Breaker to the "OFF" position.
7.1.3
Open the Fuel Choke.
Turn on the Battery Switch (Red Switch) and press the push start
7.1.4.
button.
To manual start pull the Recoil Starter until resistance is felt.
7.1.5.
This is the "Compression" point. Return the handle to its original
7.1.6.
position, and then pull swiftly.
If the generator engine fails to start after several attempts, repeat
7.1.7.
above the procedures with the Choke Lever returned to the "RUN"
position.
Do not pull the rope of the recoil starter out completely.
7.1.8.
After starting the generator allow the starter handle to return to its
7.1.9.
original position whilst still holding on to the handle.
*NOTE: If you are starting the generator for the first time, we recommend that you use the
recoil starter.
7.1.10.
After the engine has started, please return the choke lever to the "OPEN" position.
Always let the generator engine warm up sufficiently
7.1.11.
WARNING
Do not move the generator while it is running.
Be sure to ground the generator if the connected appliance is grounded.
Failure to ground the unit may lead to electrical shock.