Stopping The Generator; Oil Sensor - Gentech GP6500I Operator's Manual

Table of Contents

Advertisement

STOPPING THE GENERATOR:

8.4.
Turn off the power switch of the electric equipment and unplug
8.4.1.
the cord from the receptacle of the generator.
Turn the circuit breaker to the "OFF" position.
8.4.2.
Allow the engine to cool down for about three minutes with no
8.4.3.
load prior to switching it off.
8.4.4.
For recoil starter models turn the switch to the "OFF" position
8.4.5.
For electric start models, press the button to stop the engine and
turn off the battery switch.
8.4.6.
Close the fuel cock.

OIL SENSOR:

8.5.
The oil sensor detects a drop in the oil level in the crank case and
8.5.1.
automatically stops the engine when oil level drops below a
predetermined level.
8.5.2.
When engine has stops automatically switch off the generator's
circuit breaker and check the oil level. Refill with engine oil to the
upper level as instructed on clause 6.1, and then restart the
engine.
8.5.3.
If the engine does not start, please recheck the oil level.
CAUTION
Do not remove the OIL SENSOR PROBE when refilling
with oil. Remove the oil filler cap on the opposite side of
carburetor.
8.6.
FOUR STAGE DIGITAL METER
8.6.1.
Voltage Display Range: 160 V - 250 V (Ac single phase)
Digital Meter Display: The display shown on the digital meter 6 minutes prior to switching off the
8.6.2.
machine will be the first display shown when restarting the machine.
13
Close
Open

Advertisement

Table of Contents
loading

Table of Contents