AC APPLICATION:
8.
Check the digital meter for sufficient voltage.
8.1.1.
This generator is properly tested and adjusted and set at the
8.1.2.
factory.
Should the generator does not produce the specified voltage
8.1.3.
please contact GENTECH INDUSTRIES.
Turn off the switch (es) of the electrical appliance(s) before
8.1.4.
connecting to the generator.
8.1.5.
Insert the plug(s) of the electrical appliance(s) into the receptacle.
8.1.6.
Check the amperage of the receptacles used referring to the
TABLE on page 4 and be careful not to take a current exceeding
the specified amperage.
8.1.7.
Check that the total wattage of all appliances that is being
connected to the generator does not exceed the rated output of
the generator.
8.1.8.
Turn on the appliance switch.
*NOTE: If the circuit breaker "TRIPS" during operation the generator is overloaded, or the appliance
is defective. Stop the generator immediately and check the appliance and /or generator for
overloading.
8.2.
CONNECTING TO DOMESTIC CIRCUITS (HOUSE WIRING):
WARNING
If a generator is to be connected to residential or commercial power lines for stand-by
power during power outage, all connections must be made by a competent person/ licensed
electrician. Connection failure, or improper connection, may result in death, personal injury,
damage to the generator, damage to the appliances, damage to the building's wiring, or even
result in a fire.
When connecting the generator to the house wiring the generator output power must be taken from
8.2.1.
the 230 Volt receptacle.
A transfer switch must be installed to transfer the load from the commercial power source to the
8.2.2.
generator. This switch is necessary to prevent accidents caused by the recovery from power
outages. Use a transfer switch of the correct capacity. Install the transfer switch between the meter
and the fuse or AC Breaker Box
CAUTION
If the neutral wire of the house wiring is earthed, be sure to earth the ground terminal of the
generator. An electric shock may result if this procedure is not followed.