[10] Fusing unit
_
. General Description
®
A teflon roller is used for the upper heat roller and a
silicon roller is used for the lower heat roller.
®
The cleaning roller is impregnated
with
silicon oil to
increase the cleaning effect of the heat rollers. The upper
cleaning roller cleans the area where the thermistor is in
contact.
®
Three separator pawls are used for the upper heat roller.
@® The
upper
heat
roller surface
temperature
is set to
180°C and drops to 120°C in power standby.
2. Major Parts Replacement
(1) How to install the cleaning roller
Lower cleaning roller
DC power
supply PWB
SF-7200
1¢
AC power
Triac
Copy lamp
Heat roller
Paper
Thermistor
1) Remove
the two screws that secure the paper exit
guide.
(Front frame side)
Remove the paper exit guide securing screw.
@) Open the fusing unit.
8 Pivot the paper exit guide to the paper exit side.
10—1