NOTE: Install the Flush valve according to Flush Valve Installation Manual 0GU3093. Use the following instructions instead of installation steps 8 & 9.
Valve Body Assembly
Please read and adhere to these notes. Failure to do so could result in personal injury, risk of re or smoke and/or property damage.
- Install the product according to installation instructions.
- Install the product in the correct vertical orientation.
- Do not use or operate the product with it's covers removed.
Make sure there is enough space for the daughter card enclosure
to attach on the ush valve without interference. A minimum of
13/16" (20mm) clearance between the back of the ush valve and
the wall is required.
Do not drop enclosure! Handle with care!
1. Pull the battery tab out from daughter card enclosure.
NOTE: Red LED light will blink to indicate that procedure is functioning.
2. Connect all 4 wire harness connections. Listen for the "click"
indicating a secure connection.
3. Slide the hook of the enclosure up into the notch of the top
cover unit.
4. Hold the enclosure and top cover together and carefully guide into place
onto the valve body.
5. Secure the top cover unit to the valve body with the provided hex wrench
and screws.
6. Test Run.
7. Commit the daughter card according to GP's Instructions.
Follow the instructions in the Flush Valve Installation Instruction Manual
(0GU3093) to complete the installation.
Please contact TOTO at 888-295-8134, or Georgia Paci c at 800-890-0896 or
KOLOhelp@gapac.com for any questions regarding installation or maintenance.
0GU3096 Rev. A
KEEP THIS DOCUMENT FOR REFERENCE AND MAKE AVAILABLE FOR MAINTENANCE PERSONNEL.
ECOPOWER Exposed Flush Valve
Daughter Card Installation Manual
INCLUDED PARTS
Backup
Battery
Top Cover
BEFORE INSTALLATION
INSTALLATION PROCEDURE
Hex Wrench
Manual 0GU3093
and Screws
WARNINGS
Daughter Card
LED Light
B
D
C
Daughter Card
Enclosure
GP Part # 61000KB
TOTO Part # THP3395
Min 13/16"
(20mm)
Battery Tab
A - Daughter Card Connection
B - Generator
C - Back Up Battery
D - Solenoid Valve
A
T O P
Manual
(Refers to this document)
NOTE:
"CLICK" sound.

Advertisement

loading
Need help?

Need help?

Do you have a question about the TET1UBi2-CP and is the answer not in the manual?

Questions and answers

Summary of Contents for Toto TET1UBi2-CP

  • Page 1 7. Commit the daughter card according to GP's Instructions. Follow the instructions in the Flush Valve Installation Instruction Manual (0GU3093) to complete the installation. Please contact TOTO at 888-295-8134, or Georgia Paci c at 800-890-0896 or KOLOhelp@gapac.com for any questions regarding installation or maintenance. 0GU3096 Rev. A...
  • Page 2 ECOPOWER Exposed Flush Valve Daughter Card Installation Manual - TET1UBi2#CP/TET1LBi2#CP/TET1GBi2#CP - TET6UBi2#CP/TET6LBi2#CP/TET6GBi2#CP MAINTENANCE WARNINGS Follow these instructions carefully. Failure to do so could result in personal injury, risk of re, smoke and/or property damage. - Handle the product with care when performing maintenance. - DO NOT pull, twist or damage the wires or connectors.

This manual is also suitable for:

Tet1lbi2-cpTet1gbi2-cpTet6ubi2-cpTet6lbi2-cpTet6gbi2-cp