2Shudwlqj ,Qvwuxfwlrqv; Controls - Vermont Castings Intrepid FlexBurn 2115 Owner's Manual

Wood burning stove
Hide thumbs Also See for Intrepid FlexBurn 2115:
Table of Contents

Advertisement

2 2

2SHUDWLQJ ,QVWUXFWLRQV

A. The Intrepid FlexBurn
7ZR FRQWUROV UHJXODWH WKH SHUIRUPDQFH RI WKH ,QWUHSLG
®
)OH[%XUQ
: a primary air control VXSSOLHV R[\JHQ IRU WKH ¿UH
and a damper GLUHFWV DLU ÀRZ ZLWKLQ WKH VWRYH WR DFWLYDWH DQG
deactivate the combustion system. (Figure 2.1)
6\PEROV RQ WKH VWRYH DUH UHPLQGHUV RI WKH FRUUHFW GLUHFWLRQV
IRU XVLQJ WKH FRQWUROV 7KH ZRUGV µ/HIW¶ DQG µULJKW¶ LQ WKHVH
directions are facing the stove.
'RRU +DQGOH
Andirons
)LJXUH   7KH ,QWUHSLG )OH[%XUQ
and easy to operate.
$6LQJOH$LU &RQWURO 5HJXODWHV +HDW 2XWSXW DQG %XUQ 7LPH
The primary air control lever RQ WKH WRSULJKW RI WKH VWRYH
controls the amount of incoming air for starting, maintaining,
DQG UHYLYLQJ D ¿UH
2QFH WKH DLU FRQWURO LV PDQXDOO\ VHW D ELPHWDOOLF WKHUPRVWDW
automatically maintains the heat output at a constant level
for a more even heat over the life of the burn.
0RUH DLU HQWHULQJ WKH VWRYH PDNHV WKH ¿UH EXUQ KRWWHU DQG
faster, while less air prolongs the burn at a lower heat output
level.
)RU WKH JUHDWHVW DLU VXSSO\ DQG PD[LPXP KHDW RXWSXW EXW
WKH VKRUWHVW EXUQ WLPH  PRYH WKH OHYHU WRZDUG WKH ÀXH FROODU
)RU D ¿UH WKDW ZLOO ODVW ORQJHU ZLWK OHVV KHDW PRYH WKH OHYHU
DZD\ IURP WKH ÀXH FROODU )LJXUH 
7KLV ZRRG KHDWHU KDV D PDQXIDFWXUHGVHW PLQLPXP ORZ
EXUQ UDWH WKDW PXVW QRW EH DOWHUHG ,W LV DJDLQVW IHGHUDO
regulations to alter this setting or otherwise operate this
wood heater in a manner inconsistent with operating
instructions in this manual.
8
®

Controls

$LU &RQWURO /HYHU
'DPSHU +DQGOH
'RRU +DQGOH +ROGHU
%HKLQG OHJ
Ashdoor
+DQGOH
®
controls are conveniently located
WARNING
Vermont Castings • Intrepid FlexBurn
Low Heat
)LJXUH   The handle may be positioned anywhere between the
WZR H[WUHPHV IRU GL HUHQW KHDW OHYHOV
$ 'DPSHU 'LUHFWV $LU )ORZ :LWKLQ WKH 6WRYH
The GDPSHU E\SDVV KDQGOH on the right side of the stove
RSHUDWHV WKH GDPSHU WR GLUHFW DLU ÀRZ ZLWKLQ WKH VWRYH
The damper is open when the handle points down, enabling
VPRNH WR SDVV GLUHFWO\ LQWR WKH FKLPQH\ 7KH GDPSHU PXVW
EH RSHQ ZKHQ VWDUWLQJ RU UHYLYLQJ D ¿UH DQG DOZD\V ZKHQ
the griddle or doors are opened.
The damper is closed when the handle points forward.
6PRNH WUDYHOV WKURXJK WKH VHFRQGDU\ FRPEXVWLRQ V\VWHP
where it can be further burned, before passing up the
chimney. (Figure 2.3)
The damper should always be either fully open or fully
closed. There are no intermediate positions. When
FORVLQJ WKH GDPSHU EH VXUH WR SXOO ¿UPO\ HQRXJK WR VQDS
the handle into the locked position.
'DPSHU 3RVLWLRQV
Closed
+LJK ( FLHQF\
Mode)
2SHQ
8SGUDIW 0RGH
)LJXUH   7KH GDPSHU LV HLWKHU RSHQ RU FORVHG 7KHUH DUH QR
intermediate positions.
Note: 2SHUDWLRQ ZLWK WKH IURQW GRRUV RSHQ DQG WKH GDPSHU
in the closed position are not permitted and could cause
VPRNH VSLOODJH WR WKH LQVLGH RI WKH GZHOOLQJ
®
Owner's Manual_R22 • 2018 - ___ • 08/23
+LJK +HDW
3-90-30007345C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intrepid flexburn 2115-cat

Table of Contents