Page 1
MATTRESS Owner’s Manual Please keep and refer to this Owner’s Manual. Thank you for purchasing a Direct Supply Panacea Air Ease Mattress from Direct Supply Equipment & Furnishings . Please ® ® ® read this entire guide carefully and keep it for future reference. This guide will provide you with instructions, warnings, warranty information and other important information about your air mattress.
PRODUCT or DEVICE: Panacea Air Ease Mattress ® YOU and YOUR: The facility, community or other entity that has purchased the device. WE, US and OUR: Direct Supply Manufacturing, Inc. •: Attention! Read the instructions. 1-800-634-7328 DirectSupply.com...
The alternating pressure and limited low air loss mode on the Panacea Air Ease mattress is indicated for use as a preventive tool against further complications associated with many critically ill residents or immobility.
Warnings Read and follow all directions and warnings before using this device. • WARNING: 1. Failure to comply with all directions and warnings may result in injury or death; use only as directed. 2. This device is not suitable for all individuals. Other devices may be required. 3.
Keep carton and packing material for return shipment if it should become necessary. 2. Place the Panacea Air Ease mattress on the bed frame with the hoses exiting at the foot of the bed. 3. Secure the mattress to the bed deck using the black straps attached to the bottom of the Figure 3 mattress.
Page 7
Control Unit Operations 1. FIRMNESS DIAL: Turn the dial to adjust the pressure within the mattress, clockwise to increase pressure; counterclockwise to decrease pressure. The recommended pressure settings correspond to the user weight values around the dial. Pressure should be adjusted according to individual comfort preferences.
Page 8
Directions for Use (cont.) Use Instructions 1. With power connected, turn the power switch to the ON position. Wait approximately 30 minutes for the mattress to fully inflate. It is recommended to set the mattress to Static Mode and firmness to the maximum setting to promote faster initial inflation. a.
Transportation & CPR Transportation 1. Disconnect the hose from the pump and quickly place the cap over the end of the hose to prevent air loss. 2. Check the fit of the cap for leaks. 3. Verify the red CPR valve at head-end of the mattress is closed and no air is escaping. 4.
Cleaning Mattress Only the outer cover requires cleaning and maintenance. Disassembly of the mattress for cleaning of internal components is not recommended. The cleaning of the air mattress should be carried out in an aerated state (to prevent the detergent from penetrating into the inner cavity of the air mattress).
It is important to periodically test the Panacea Air Ease mattress control unit to verify the proper functionality. Lack of regular maintenance can result in poor or reduced resident support.
Troubleshooting Mattress will not inflate or every other cell is not inflating: • Disconnect the control unit and make sure air is flowing from the open ports. This is done by disconnecting the control unit from the mattress and physically feeling the air blowing out from one port and then the other.
Page 13
EMI (Electromagnetic Interference) This product conforms to the electromagnetic compatibility requirement of IEC 60601-1-2:2014 standard. This product shall be used and operated in accordance with the instructions and Manufacturer’s Statement below. Manufacturer’s EMC Declaration • WARNING: Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the device.
(cont.) Enclosure Port Immunity From RF Wireless Communications Equipment (IEC 60601-1-2) 1.3 Test Specifications for ENCLOSURE PORT IMMUNITY to RF Wireless Communications Equipment Test IMMUNITY Banda Service Modulation Maximum Distance Frequency Test LEVEL (MHz) Power (W) (MHz) (V/m) Pulse 380 - 390 TETRA 400 Modulation 18 Hz...
Limited Warranty We, Direct Supply Manufacturing, Inc. offer to you, as the original purchaser, a warranty for the Direct Supply Panacea Air Ease Mattress. Our warranty applies for the limited warranty period stated ® ® below. If any product or product part listed below is defective in material or workmanship during the applicable limited warranty period, we will repair or replace it at our cost.
Need help?
Do you have a question about the Panacea and is the answer not in the manual?
Questions and answers