Adamson Systems Engineering CS10 User Manual page 8

Table of Contents

Advertisement

S
E
R
I
E
S
Power
RMS Long-Term
RMS Idle
Table 1 - Single cabinet current draw
Current draw for the CS10 is dynamic and fluctuates as operating levels change.
The Power Distribution System (PDS, 914-0002 - 110 V/914-0003 - 230 V) provides six individually protected
AC circuits of 208/230 V, 16 A. When using the Adamson PDS, you can link a maximum of six CS10
loudspeakers per circuit.
When wiring an AC cable for use with this product in
a single-line system, use the wiring scheme described
below in Table 2 and illustrated with Fig. 1. All work
must be completed by a qualifi ed technician.
powerCON True1 AC Cable Input Connector
User Manual
100 V
115V
3.70
3.22
1.04
0.90
Hot or Live (L)
Neutral (N)
Protective Earth /
Ground (E or PE)
Table 2
120 V
208 V
230 V
3.10
1.78
1.60
0.86
0.50
0.45
Blue
Brown
Blue
Green and Yellow
powerCON True1 AC Cable Output Connector
240 V
1.54
0.43
Green and Yellow
Brown
Fig. 1