Contents Symbols Safety & Warnings Status LED Product Overview Power Connectivity Rack Mounted Systems Control Suite Technical Specifications Symbols This symbol alerts the user that there are important operating and maintenance instructions in the literature accompanying this appliance This symbol alerts the user to the presence of voltages that can cause dangerous electric shock This symbol alerts the user to the weight of the appliance that can cause muscle strain or back injury This symbol alerts the user that the appliance can be hot to the touch and should not be touched without taking care and instruction...
A qualified technician must be present during the installation and use of this product. This product is capable of producing extremely high sound pressure levels and should be used according to the specified local sound level regulations and good judgement. Adamson Systems Engineering will not be liable for damages caused by any possible misuse of this product.
Green Solid STATUS CAUTION THRU Amplifier Off Amber Solid RISK OF ELECTRIC SHOCK ADAMSON SYSTEMS ENGINEERING DO NOT OPEN www.adamsonsystems.com MADE IN CANADA FABRIQUÉ AU CANADA Amplifier Clipping Flashing General Fault Solid In an effort to continuously improve its products, Adamson releases updated software, presets and standards for its products.
Product Overview The CS7 is an ultra-compact, powered, intelligent, line array enclosure designed for medium throw applications. It contains two symmetrically arrayed 7” LF transducers, and a 3” HF compression driver mounted onto an Adamson waveguide. The high frequency waveguide is designed to couple multiple cabinets across the entire intended frequency band without loss of coherence.
Power The CS7 utilizes advanced loudspeaker technology, augmented with advanced power processing. Understanding electrical safety is critical in the safe operation of this product. This product must always be grounded/earthed. Do not ground-lift the AC cable - never use a ground-lifting adapter or cut the AC cable ground pin.
Page 8
Power 100 V 115V 120 V 208 V 230 V 240 V RMS Long-Term 3.45 A 3.00 A 2.88 A 1.66 A 1.50 A 1.44 A RMS Idle 1.04 A 0.90 A 0.86 A 0.50 A 0.45 A 0.43 A Peak 20.70 A 18.00 A...
Connectivity On-board Digital Signal Processing (DSP) is accessed via two data ports on the rear of the cabinet. These ports are used to stream AVB audio as well as transmit AES70 control data. All CS-Series loudspeakers are configured to receive two separate LAN signals on a single data link. The CS Network Distribution System (NDS, 905-0039) combines both LANs on one ethernet cable.
Input 100V - 240V, AES / ANALOG OUTPUT MUST BE GROUNDED / EARTHED 50/60Hz, 1A festival environment. 15 Vdc WARNING ADAMSON SYSTEMS ENGINEERING Serial Sticker Here WORD CLOCK OUT MUST BE GROUNDED www.adamsonsystems.com / EARTHED MADE IN CANADA FABRIQUÉ AU CANADA...
Control Suite Adamson CS is a single software platform which allows the user to design and deploy a system, all from a single interface. From room design and simulation to connectivity and diagnostics, this unified platform reduces the need for additional software in order to properly deploy and deliver complete audio systems.