Rack Mounted Systems - Adamson Systems Engineering CS10 User Manual

Table of Contents

Advertisement

S
E
R
I
E
S

Rack Mounted Systems

Gateway (913-0003) - The AVB on-ramp into the CS-Series ecosystem,
the Gateway is a 16x16 matrix with 16 channels of user accessible DSP,
containing dual-LAN, Milan AVB, AES/EBU, and analog connections. The
Gateway converts AVB to and from analog and AES/EBU. An extremely
powerful tool, the Gateway's network connectivity also allows for integrating
other systems link broadcast feeds or matrixing multiple consoles in a
festival environment.
Bridge (913-0005) - The Bridge is designed to replace existing network
infrastructure in Adamson's E-Rack, allowing users to seamlessly integrate
CS-Series loudspeakers into their existing inventories by converting dual-
LAN, Milan AVB signal to AES/EBU for networking to existing Lab Gruppen
amplifi ers, while also offering six channels of DSP per unit.
Network Distribution System NDS (905-0039) - The NDS is a network and
analog patch bay that allows users to send redundant audio and control to
CS-Series loudspeakers on a single network cable. The NDS combines LAN
A and B network ports using two external AVB enabled switches.
Power Distribution System PDS (914-0002/914-0003) - Available in 110 V
(2x L21-30) and 230 V (32 A CEE) models, the PDS is designed to ensure that
all components of the CS-Series ecosystem receive ample power. The PDS
provides six circuits of 208 V or 230 V, 16 A offered via powerCON or Socapex
outputs. An integrated data port allows users to monitor consumption data
via ArrayIntelligence, both per power output and for overall draw.
User Manual
Gateway Front
1 - 8
1 - 4
INPUTS
PRI
STATUS
OUTPUTS
SEC
Gateway Back
AES / ANALOG INPUT
P1
P2
P3
1
2
3
4
5
6
7
WARNING
AES / ANALOG OUTPUT
MUST BE GROUNDED / EARTHED
S1
S2
S3
1
2
3
4
5
6
7
ADAMSON SYSTEMS ENGINEERING
Serial Sticker Here
www.adamsonsystems.com
MADE IN CANADA
FABRIQUÉ AU CANADA
Bridge Front
P1
P2
P3
S1
S2
S3
DATA
AES 1
Bridge Back
NDS Front
FIBRE IN / THRU
RJ45 IN/THRU
ANALOG 1
OUTPUT
P1
P2
P1
P2
L1
A1-1
L2
ANALOG 2
S1
S2
S1
S2
L4
A2-1
L5
NDS Back
OUT 1
OUT 2
OUT 3
PRI
OUT 4
OUT 5
OUT 6
SEC
PDS Front
200-240V~16A
200-240V~16A
50/60 Hz
50/60 Hz
1
3
5
STATUS
2
4
PDS Back
AUX OUTLET 2
WARNING
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING
AUX OUTLET 1
100 -120V~ 50/60Hz 5A
THIS EQUIPMENT IS SUPPLIED BY TWO SOURCES OF POWER
TWO CONDITIONS:
100 -120V~ 50/60Hz 5A
No user serviceable parts inside. Installation and servicing to be
1. THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE.
carried out by authorized personnel only
2. THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY
CAUSE UNDESIRED OPERATION.
Aux Outlets 1&2 Supplied
from phase 1 of Power
Inlet A, via Aux breaker
on front panel. 5A max.
WARNING
MUST BE GROUNDED / EARTHED
Serial Sticker Here
Power Inlet A
Power Inlet B
3Ø/N/PE ~ 120/208V
3Ø/N/PE ~ 120/208V
50/60Hz 28/16A Y/∆
50/60Hz 28/16A Y/∆
ADAMSON SYSTEMS ENGINEERING
www.adamsonsystems.com
MADE IN CANADA
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING
AUX OUTLET 1
AUX OUTLET 2
TWO CONDITIONS:
220 -240V~ 50/60Hz 5A
220 -240V~ 50/60Hz 5A
WARNING
1. THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE.
No user serviceable parts inside.
Installation and servicing to be carried out by authorized personnel only
2. THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY
CAUSE UNDESIRED OPERATION.
Aux Outlets 1&2 Supplied
from phase 1 of Power
Inlet A, via Aux breaker
on front panel. 5A max.
WARNING
MUST BE GROUNDED / EARTHED
Serial Sticker Here
Power Inlet A
3Ø/N/PE ~ 220/240V
50/60Hz 28/32A Y
ADAMSON SYSTEMS ENGINEERING
www.adamsonsystems.com
MADE IN CANADA
PRI
SEC
USB
GATEWAY
AC
8
WORD CLOCK IN
Input 100V - 240V,
50/60Hz, 1A
8
15 Vdc
WARNING
WORD CLOCK OUT
MUST BE GROUNDED
/ EARTHED
AES 2
AES 3
BRIDGE
A1-2
L3
A1-3
A2-2
L6
A2-3
NETWORK DISTRIBUTION SYSTEM
PRI
SEC
All Outputs
200-240V~16A
50/60 Hz
6
OUTPUT 1- 6
POWER DISTRIBUTION SYSTEM
FABRIQUÉ AU CANADA
DATA
FABRIQUÉ AU CANADA
DATA
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs series

Table of Contents