NX-820(G)/820
Item
Panel tuning mode
*7: Because Low RSSI at –118dBm (NXDN Narrow) is adjusted by adjusting Low RSSI at –118dBm (Analog Narrow), it is not necessary to adjust Low
RSSI at –118dBm (NXDN Narrow).
7. High RSSI
1) Adj item: [HRSS]
at -80dBm
Adjust: [∗∗∗.]
*8
2) Adj item:
[H.RSS]→
[Analog
[H.R.SS]→
Narrow]
[H.R.S.S]→
[H.R.S.S.]→
[H.R.S.S._.]
SSG output:
-80dBm (22.4uV)
(MOD: 1kHz/±1.5kHz)
[Analog
1) Adj item: [HRSS]
Wide 4k]
Adjust: [∗∗.∗.]
2) Adj item:
[H.RSS]→
[H.R.SS]→
[H.R.S.S]→
[H.R.S.S.]→
[H.R.S.S._.]
SSG output :
-80dBm (22.4uV)
(MOD: 1kHz/±2.4kHz)
[Analog
1) Adj item: [HRSS]
Wide 5k]
Adjust: [∗.∗.∗.]
2) Adj item:
[H.RSS]→
[H.R.SS]→
[H.R.S.S]→
[H.R.S.S.]→
[H.R.S.S._.]
SSG output :
-80dBm (22.4uV)
(MOD: 1kHz/±3kHz)
[NXDN
1) Adj item: [HRSS]
Very Nar-
Adjust: [∗∗∗]
row]
2) Adj item:
[H.RSS]→
[H.R.SS]→
[H.R.S.S]→
[H.R.S.S.]→
[H.R.S.S._.]
SSG output :
-80dBm (22.4uV)
(MOD: 1kHz/±1.5kHz)
*8: Because "RSSI at –80dBm adjust" of NXDN Narrow is adjusted by adjusting "RSSI at –80dBm adjust [Analog Narrow]", it is not necessary to adjust
"RSSI at –80dBm adjust" of NXDN Narrow.
54
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [High
SSG
RSSI (Analog Nar-
row)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±1.5kHz)
1) Adj item:
[High RSSI (Analog
Wide 4k)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±2.4kHz)
1) Adj item:
[High RSSI (Analog
Wide 5k)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±3kHz)
1) Adj item:
[High RSSI (NXDN
Very Narrow)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±1.5kHz)
Measurement
Test-
Termi-
Unit
Unit
nal
ANT
Ext.SP
con-
nector
Adjustment
Specifi cations/
Parts
Method
[Panel tuning mode]
After input signal
from SSG, press
[
] key to store
the adjustment
value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
Adjust with the ana-
log signal.
Remarks