• It must have a check valve in the discharge line to
prevent waste water return to the pump.
• It must have an overflow protection control which will
shut off power to the ice maker in the event of a pump
failure.
• It must have an operating temperature range of 50°F
to 110°F (10°C to 40°C).
IMPORTANT
IMPORTANT
In the event of a power outage, restricted drain or
pump failure, the failure to use the U-Line P60 drain
pump or a pump with the above listed
specifications, could result in substantial water
leakage and pooling with severe and costly water
damage and related consequential damages and
harm.
Stand Pipe
P60 Pump Required
Figure 8
Disposal Assembly
P60 Pump Required
Air Gap
(Optional Hook-Up)
Figure 9
Waste
Shut-Off
Valve
Cold
Water
Hot
Water
Waste
ULIN_0571a_A
Waste
Cold
Water
Hot
Water
Shut-Off
Valve
ULIN_0572a_A
CLR2160, CLRCO2175
Y-Branch Tailpiece
P60 Pump Required
(Optional Hook-Up)
Figure 10
WARNING
To prevent accidental electrocution, make certain
that the floor surfaces surrounding the unit are
dry whenever power is removed from, or applied
to, the unit.
5/8" x 5/8"
Barb Connector
Figure 11
To connect to drain:
1. Slide 2 hose clamps onto the drain connection on the
rear of the appliance.
2. Insert the barbed fitting halfway into this connection.
3. On the other end of this barbed fitting attach the 5/8"
braided tubing.
4. Slide a clamp on each side of the barbed fitting as
shown (Figure 11).
5. Insulate the drain line, if necessary to prevent
condensation. Go on to Final Water/Drain Connection.
Page 8.
Air Gap
Shut-Off
Valve
Hot
Water
ULIN_0573a_A
Drain Fitting from
Back of Unit
Worm Clamps
Drain Line
ULIN_S_0166b2_A
Waste
Cold
Water
7