Advertisement
Model Number: H4500
Humidifying Mode: Combination
Power Supply: 120V 60Hz
Power Consumption: 140W
Maximum Humidity Capacity: High Mist - 1.4 gallons/24 hours; Low Mist - 0.5 gallons/24 hours
Tank Capacity: 2.4 gallons (9.08 liters)
Successive Humidity Hours: Up to approximately 120 hours depending on environmental conditions
Dimensions: Width - 11 in/ 27.94cm; Length - 14.75 in/37.47cm; Height - 11.75 in/29.85cm
Weight: 8.32 lbs/ 3.78 kg (not including packaging)
Select humidifying temperature based on need. Warm humidity will use more power but will humidify your room quicker.
NOTE: It may take 10-15 minutes before warm humidity is created. The mist may not feel especially warm due to the fact it is so fine and is cooled rather quickly from the air in your home.
TEST: To test if the warm mist is functioning properly, place the unit in a 200 square foot room or smaller and close the door. Allow the unit to run for approximately 30 minutes or more. Reenter the room - if unit is functioning properly - the room will feel moderately warmer.
TEST: Another way to check if the unit is functioning properly is by feeling along the base of the unit. The base should feel warm to the touch.
When the unit is low on water the Refill LED on the front panel will light up, and the unit will shut off. Simply add more water to continue use. Unit will automatically resume running when water tank has been refilled.
The humidity volume may be adjusted based on need by using the adjustment knob on the front panel.
Unlike other humidifiers that grow slimy mold and mildew, the pureguardianTM Ultrasonic Humidifiers use Silver CleanTM technology embedded in the tank to fight the growth of mildew and mold on the surface of the water tank.
Pour excess water out of the unit, but do not allow it to enter the blast port. Wash out the unit with fresh water using the cleaning brush and a soft cloth as needed.
Wipe the surface of the unit with a soft, damp cloth if needed.
If water spots remain in the water tank, wipe the inside down with a soft cloth. Do NOT use soap or detergents.
Remove the tank (Fig. 1) and use the enclosed cleaning brush to regularly remove build up and deposits from the disk area (Fig. 2). **Diluted white vinegar will help to prevent this build up.
PROBLEM | SOLUTION |
Water vapor and humidity are not produced. | Power Plug: Unplug and then try again. Power Failure: When the power is returned, try again. Tank Installation: Make sure the tank is correctly attached. |
Air blows but water vapor is not produced. | Excessive Water: Remove a certain amount of water from the tank. The desired humidity is lower than the current temperature: Increase the desired humidity. Detergent residue in tank: Wash the tank out and try again. |
Humidity level is low. | The surface of the ultrasonic disk is dirty: Clean the disk. The water in the unit is too cold: Replace with cool, but not cold water. |
Warm humidity is not produced. | It may take 10-15 minutes before warm humidity is created. |
The humidity has a bad smell. | Poor maintenance or dirty water: Clean the product thoroughly, and fill it with fresh water. |
White dust is forming on nearby furniture. | Hard water may deposit a certain amount of dust. Dust in the air also settles because of added humidity in the room. Use distilled water if this becomes a nuisance. * Decalcification Filter available (FLTDC) at www.guardiantechnologies.com or through Customer Service 1.866.603.5900. |
Increased noise level when unit is turned on. | Unit must be placed on a flat, level, hard surface. Make sure that the unit is NOT placed on carpeting, towels, blankets or other soft surfaces. |
The floor surrounding the humidifier is becoming excessively wet. | Make sure the unit is atleast waist high. Turn the spray control down. Point spray nozzle away from objects. |
This product should be used only in accordance with the specifications outlined in this manual.
Usage other than what has been specified here may result in serious injury.
Failure to comply with the warnings listed above may result in electric shock or serious injury.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the H4500 that isn't answered in the manual? Leave your question here.