PRODUCT SPECIFICATIONS AND PARTS

PARTS

PARTS

FUNCTIONS AND FEATURES

REFILL INDICATOR

When the unit is low on water the Refill Indicator LED on the base will change from green to red, and the unit will shut off. Simply add more water to continue use.

MIST DIRECTOR

The mist director can be selected through 360° by turning the spout.

SILVER CLEAN TECHNOLOGY

Unlike other humidifiers that grow slimy mold and mildew, the pureguardianTM Ultrasonic Humidifier uses Silver CleanTM technology embedded in the tank to fight the growth of mildew and mold on the surface of the water tank.

NIGHT LIGHT

An LED illuminates the tank for a soft glow night light.

CLEANING BRUSH STORAGE

CLEANING BRUSH STORAGE

DIRECTIONS FOR USE

SET UP

Select a firm, level, flat location - at least six inches (15 cm) from any wall or object for proper air flow. Place the humidifier on a water-resistant surface, as water can damage furniture and some flooring. Do not place unit directly on carpet, towels, blankets or other absorbent surfaces.

Guardian Technologies will not accept responsibility for damage caused by water spillage.

FILLING

Make sure unit is unplugged.

  1. Separate the tank from the base of the unit.
    FILLING - Step 1
  2. Flip over water tank and open the tank lid, turning it to the left.
    FILLING - Step 2
  3. Pour cool, clean water directly into the tank. Do not pour anything but water into the tank.
    FILLING - Step 3
  4. Close the tank lid, turning it to the right.
    FILLING - Step 4
  5. Attach the tank to the base of the unit and plug adapter into port on lower back of unit. Plug into power outlet.
    FILLING - Step 5
  6. Turn dial to power on and adjust to preferred mist.
    FILLING - Step 6
  • Green LED will illuminate when running.
  • Red LED indicates the unit needs refilling.
  • Always unplug the unit before servicing it in any way.
  • Do not submerse the unit in water, or allow water to enter the inside of the unit.

CLEANING

  • Always unplug the unit before servicing in any way.
  • The water temperature of the water remaining in the unit after use may be high, allow time for it to cool.

GENERAL CLEANING

  • Inside the base of the unit. Pour excess water out of the unit. Wash out the unit with fresh water using the cleaning brush and a soft cloth as needed. Do not submerse the base of the unit into water, or allow water to enter inside the dry air exhaust port of the unit.
  • Water tank. Empty water tank. Remove mist nozzle and clean the mist tube with fresh water and a light brush (bottle cleaning brush is recommended).
  • Outer surface of the unit. Wipe the surface of the unit with a soft, damp cloth if needed. If you notice an accumulation of water during usage, reduce humidity and dry outer surface with a cloth.

DESCALING

  • Depending on usage and water type, cleaning to remove scale may be required weekly or every other week to optimize unit performance.
  • If you live in a hardwater area, we recommend the use of distilled water for your humidifier. This will help reduce the precipitation of minerals or 'white dust'.
  • Do not clean the unit or water tank with detergents or cleaning chemicals of any kind.

ULTRASONIC DISK

  1. Unplug unit.
  2. Remove the tank and empty all water from unit base and tank.
  3. Locate the ultrasonic disk on the inside center of the base unit. (Fig. 1)

    Do not scrub or scrape the ultrasonic disk.
  4. Use ONLY the enclosed cleaning brush to gently clean disk and remove build up and deposits.

If scale becomes difficult to remove with brush:

  1. Fill the Base with: mixture of 1 tsp. white vinegar and 1 tsp. water.
  2. Let solution stand for 5 minutes.
  3. With the vinegar in the Base, clean all interior surfaces with a soft cloth or brush to help remove scale.
  4. Also check mist nozzle and mist tube in water tank. Clean as needed.
  5. Rinse the Base thoroughly with water to remove scale and vinegar solution.

END OF SEASON STORAGE

  • Follow the Cleaning and Descaling instructions when the humidifier will be stored at the end of the season.
  • Dry the humidifier completely before storing. DO NOT store with water inside the Base or Water Tank.
  • Pack the unit in its original carton and store in a cool, dry location.

NOTE: IF YOU EXpERIENCE A pRObLEM DO NOT ATTEMpT TO OpEN THE MOTOR HOUSING YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER OR pERSONAL INJURY.

TROUBLESHOOTING GUIDE

PROBLEM SOLUTION
Water vapor & humidity are not produced.

Power Plug: Unplug and then try again.

Power Failure: When the power is returned, try again.

Tank Installation: Make sure the tank is correctly attached. The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.

Air blows but water vapor is not produced.

Excessive Water: Remove a certain amount of water from the tank.

The desired humidity is lower than the current temperature: Increase the desired humidity.

Detergent residue and/or oil ingredients from cosmetics, etc may be in tank; wash out tank and try again.

The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.

If you use hard water, replace with softer water.

Humidity level is low.

The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.

The water in the unit is too cold: Replace with cool, but not cold water.

Damage on the ultrasonic disk: Contact Customer Service 1.866.603.5900

The humidity has a bad smell. Poor maintenance or dirty water: Clean the product thoroughly, and fill it with fresh water.
White dust is forming on nearby furniture. Hard water may deposit a certain amount of dust. Dust in the air also settles because of added humidity in the room. Use distilled water if this becomes a nuisance.
Light on front of unit is red. Unit has stopped working. No or low water. Unplug unit and refill tank.
Water is accumulating outside of unit or area surrounding unit.

Saturation of humidity. Lower mist control setting.

Unit not level and water is accumulating. Unplug and place on level surface. Point spray away from objects. Raise unit on a water-resistant level surface 2-3 feet off of floor.

Increased noise level. Unit must be placed on a flat, level, hard surface. Make sure it is NOT placed on a soft or absorbent surface.

WARNINGS

Failure to comply with the warnings listed below may result in electric shock or serious injury.

warningThis product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.


THE CORDS, WIRES AND/OR CABLES SUPPLIED WITH THIS PRODUCT CONTAIN CHEMICALS, INCLUDING LEAD OR LEAD COMPOUNDS, KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND EARTH DEFECTS OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USING.


  • To reduce the risk of severe burns, keep this product out of the reach of children and pets.
  • Disassembly, repair or remodeling by an unauthorized person may result in serious harm and will void the manufactures warranty.
  • Always place this humidifier on a firm, flat & level surface. This humidifier may not work properly on an uneven surface.
  • Do not place this product on cloth, carpet or an absorbent surface. This may block air inlet.
  • This product releases mist. Do not place this humidifier directly on wood furniture, flooring or any surfaces that could be damaged by water. Manufacturer does not accept any liability for damage in the case of the unit being placed incorrectly.
  • Do not use if the plug is damaged or loose.
  • Before filling or cleaning the unit, make sure it is unplugged.
  • Once the humidifier has been plugged in, do not tilt or move the unit.
  • Do not remove the water tank from the unit while it is on.
  • Do not handle the plug with wet hands.
  • Do not excessively bend, twist, pull or damage the power cord.
  • Avoid placing this product where the humidity spout is pointed directly at an object or person.
  • Do not inhale the mist/vapor expelled from the product or drink water from the tank.
  • Do not fill the water tank with hot or boiling water.
  • Do not use this product in direct sunlight or near a heat source such as a stove, heater or radiator.
  • If the water tank becomes cracked or damaged, do not use.
  • Do not keep this product running for an extended period of time.
  • Unplug the cord when unit is not in use for an extended period of time and/or when no one is home.
  • Do not keep water in the tank when not in use for an extended period of time.

READ AND SAVE THESE INSTRUCTIONS

Failure to comply with the warnings listed below may result in electric shock or serious injury.

  • Do not clean the unit, water tank or water reservoir with detergents or chemicals of any kind.
  • The use of water additives including ethereal/essential oils, fragrances, eucalyptus, water conditioners, etc. will damage the appliance materials and as a consequence the whole unit. Any use of such additives will void the manufactures warranty.
  • Do not use this product near any other electronic device.
  • Do not cover the spray spout at any time during use. Do not put anything on or in the tank.

  • Neither humans nor animals can hear the high frequency vibrations.
  • When unplugging from outlet hold humidifier securely.
  • Do not place cord over objects.
  • Do not get water in or on the power cord or where it connects to the product. Do not use near a sink.
  • Do not touch the water tank during operation.
  • Do not submerse the unit in water or pour water on the unit or in the humidity spout.
  • When emptying water from water tank, pour on drain side.
  • Do not cover the spout with cloth or hand and do not use without the spout.
  • Use clean or distilled water in tank. Hard water areas will require more frequent cleaning.

SPECIFICATIONS

  • MODEL NUMBER: H1010
  • HUMIDIFYING MODE: Ultrasonic
  • POWER SUPPLY: AC120V, 60Hz (Adapter AC120V / AC 24V)
  • POWER CONSUMPTION: 18W
  • HUMIDITY CAPACITY: About 57cc/hr low speed; 106cc/hr high speed
  • TANK CAPACITY: 0.21 gallons
  • SUCCESSIVE HUMIDITY HOURS: Up to 14 hours on low depending on environmental conditions
  • DIMENSIONS: Width - 8.2 inches; Height - 8.9 inches; Depth - 4.6 inches
  • WEIGHT: 1.3 pounds (not including packing adapter)

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Guardian H1010 - PureGuardian Ultrasonic Cool Mist Humidifier Manual

Advertisement

Need help?

Need help?

Do you have a question about the H1010 and is the answer not in the manual?

Questions and answers

Table of Contents