Guardian H3250 - PureGuardian 1.5-Gallon 100-Hour Ultrasonic Warm and Cool Mist Tower Humidifier and Aroma Tray Manual
![]()
PRODUCT SPECIFICATIONS AND PARTS
SPECIFICATION
SHUMIDIFYING MODE: Cool/Warm Mist
TANK CAPACITY: 1.5 galons
SUCCESSIVE HUMIDITY HOURS: Up to approximately 100 hours between tank refils when on lowest mist setting.
PARTS
![Guardian - H3250 - OVERVIEW OVERVIEW]()
![Guardian - H3250 - CONTROL PANEL BUTTON FUNCTIONS CONTROL PANEL BUTTON FUNCTIONS]()
FEATURE HIGHLIGHTS
NIGHT LIGHT
An LED iluminates the tank for a soft glow night light.
TIMER
Preset the humidifier to automaticaly turn off in 4, 8, or 12 hours.
POWER
Turns humidifier ON/OFF.
MIST CONTROL
The spray volume or amount of mist that is produced by the unit can be adjusted to threelevels based on need.
WARM/COOL MIST OPTION
Choose Warm Mist Control for Warm Mist.
REFILL INDICATOR
When the Water Refil button lights up it is time to refil the water tank.
SILVER CLEAN TECHNOLOGY
Unlike other humidifiers that grow slimy mold and mildew, the pureguardianHumidifier uses Silver Clean™ technology embedded in the tank to fight the growth of™ Ultrasonic mildew and mold on the surface of the water tank.
AROMATHERAPY TRAY
Add your favorite essential oil to the Scent Pad.
CONTROL PANEL LIGHTS
Automaticaly shuts off after 5 seconds. It wil light up again when any control button is pushed.
DIRECTIONS FOR USE
SET UP
Select a firm, level, flat location - at least six inches (15 cm) from any wal or object for proper air flow. Place the humidifier on a water-resistant surface, as water can damage furniture and some flooring. Do not place unit directly on carpet, towels, blankets or other absorbent surfaces.
Guardian Technologies will not accept responsibility for damage caused by water spillage.
NOTE: Handle is designed to carry tank, not unit.
FILLING
Make sure unit is unplugged.
- Lift the water tank by the handle to separate the tank from the base of the unit.
![Guardian - H3250 - DIRECTIONS FOR USE - FILLING - STEP 1 DIRECTIONS FOR USE - FILLING - STEP 1]()
- Depending on your water source choose either tank LID A (fill sideways) or tank LID B (fill lengthwise). Remove lid by turning it to the left.
![]()
Remove only 1 lid when filling.
![Guardian - H3250 - DIRECTIONS FOR USE - FILLING - STEP 2 DIRECTIONS FOR USE - FILLING - STEP 2]()
- Pour cool, clean water directly into the tank. Do not pour anything but water into the tank. Close the tank lid, turning it to the right. It is important to FIRMLY secure cap after filling the tank with water.
- Return the tank.
- Guide tank into base.
![Guardian - H3250 - DIRECTIONS FOR USE - FILLING - STEP 3 DIRECTIONS FOR USE - FILLING - STEP 3]()
- Lift tank slightly to connect tank to the top edge of the control panel.
![]()
- Add a few drops of your favorite essential oil to the pad in the tray. (Oil not included)
![]()
DO NOT add oils or other additives directly into the water tank. Add only to the pad in the tray. Oils added to the tank will damage the tank and the whole unit. Any use of such additives in the tank will void the manufacturers warranty.
Pureguardian essential oils and replacement pads sold separately at www.guardiantechnologies.com
POWER BUTTON
Before turning on make sure there is water in the unit. Press the Power Button.
![]()
Warm Humidification Control
Press to select warm mist. When warm is selected, LED will light. Water temperature is maintained at room temperature for cool setting and 80 degrees for warm. Allow 15 minutes for water to warm.
![]()
CONTROL OPERATION
NOTE: If control panel lights are off - push any button to wake up, then proceed with control operation below.
- Night Light Feature
Press the Night Lamp button to turn night light on/off.
![]()
- Timer
Press the Timer button to select either 4, 8, or 12 hours. The unit will turn off in that time.
![]()
- Mist Control Button
When you press the Mist Control button there are three options:
Press once for LOW
Press twice for MEDIUM*
Press three times for HIGH
*Medium is default setting.
![]()
- Water Refill Indicator
When the unit is low on water the Refill LED on the front panel will light up, and the unit will shut off. Simply add more water to continue use. Unit will automatically resume running when water tank has been refilled.
![]()
NOTE: The humidifier is equipped with a safety device that will automatically shut the unit off when activated. To restart, unplug for 5 seconds, replug then press the power button. If the unit continues to shut down, there may still be an abnormal condition and the unit may need service. Call Customer Service.
CLEANING
CLEANING
- Always unplug the unit before servicing in any way.
- The water temperature of the water remaining in the unit after use may be high, allowtime for it to cool.
GENERAL CLEANING
- Inside the base of the unit. water using the cleaning brush and a soft cloth as needed. Pour excess water out of the unit. Wash out the unit with fresh. Do not submerse the base of the unit into water, or allow water to enter inside the dry air exhaust port of the unit.
- Water tank. and a light brush (bottle cleaning brush is recommended).Empty water tank. Remove mist nozzle and clean the mist tube with fresh water
- Outer surface of the unit. If you notice an accumulation of water during usage, reduce humidity and dry outer surface with a cloth. Wipe the surface of the unit with a soft, damp cloth if needed.
DESCALING
- Depending on usage and water type, cleaning to remove scale may be requiredweekly or every other week to optimize unit performance.
- If you live in a hard water area, we recommend the use of distilled water for yourhumidifier. This will help reduce the precipitation of minerals or 'white dust'.
- Do not clean the unit or water tank with detergents or cleaning chemicals of any kind.
ULTRASONIC DISK
- Unplug unit.
- Remove the tank and empty al water from unit base and tank.
- Locate the ultrasonic disk on the inside center of the base unit.
- Use ONLY the enclosed cleaning brush to gently clean disk and remove build up and deposits.
Do not scrub or scrape the ultrasonic disk.
Ultrasonic Disk
*Clean the disk with the brush only. No other cleaning tool should be used. BRUSH ONLY.
![Guardian - H3250 - ULTRASONIC DISK ULTRASONIC DISK]()
CLEANING
If scale becomes difficult to remove with brush:
- Fil the Base with: mixture of 1 tsp. white vinegar and 1 tsp. water.
- Let solution stand for 5 minutes.
- remove scale. With the vinegar in the Base, clean al interior surfaces with a soft cloth or brush to help
- Also check mist nozzle and mist tube in water tank. Clean as needed.
- Rinse the Base thoroughly with water to remove scale and vinegar solution.
Are minerals in your water producing white dust?
Try Decalcification Cartridge FLTDC20.
Look for cartridge
at your local retailer or visit www.guardiantechnologies.com
![]()
END OF SEASON STORAGE
- Follow the Cleaning and Descaling instructions when the humidifier will be stored at the end of the season.
- Dry the humidifier completely before storing. DO NOT store with water inside the Base or Water Tank.
- Pack the unit in its original carton and store in a cool, dry location.
NOTE: IF YOU EXPERIENCE A PROBLEM DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER OR PERSONAL INJURY.
TROUBLE SHOOTING GUIDE
PROBLEM | SOLUTION |
Water vapor and humidity are not produced | Power Plug: Unplug and then try again. Power Failure: When the power is returned, try again. Tank Instalation: Make sure the tank is correctly attached. The surface of the ultrasonic disk is dirty: Clean ultrasonic disk. |
Air blows but water vapor is not produced | Excessive Water: Remove a certain amount of water from the tank. Increase mist setting. Detergent residue and/or oil ingredients from cosmetics may be in tank; wash out tank and try again. The surface of the ultrasonic disk is dirty: Clean ultrasonic disk. If you use hard water, replace with softer water. |
Humidity level is low | The surface of the ultrasonic disk is dirty: Clean ultrasonic disk. The water in the unit is too cold: Replace with cool, but not cold water. Damage on the ultrasonic disk: Contact Customer Service |
Warm humidity is not produced | It may take 10-15 minutes before warm humidity is created. The mist may not feel warm due to the fact it is so fine and is cooled rather quickly from the air in your home. Test by either feeling the base of the unit which should be warm to the touch or by allowing the unit to run for approximately 30 minutes on warm setting in a closed 200 sq. foot room or smaller. The room should feel moderately warmer if the unit is working properly. |
The humidity has a bad smel | Poor maintenance or dirty water: Clean the product thoroughly, and fil it with fresh water. |
| Hard water may deposit a certain amount of dust. Dust in the air also settles because of added humidity in the room. Use distilled water if this becomes a nuisance. * Decalcification Filter available at www.guardiantechnologies.com or through Customer Service |
Unit has stopped working | No or low water. Unplug unit and refil tank. Check timer has not been set. |
Unit shuts off unexpectedly or does not operate. | Check that the safety device triggered. To restart, unplug for 5 sec/replugthen press the power button. Cal Customer Service. |
Water is accumulating outside of unit or area surrounding unit. | Saturation of humidity. Lower mist control setting. Unit not level and water is accumulating. Unplug and place on level surface. Point spray away from objects. Raise unit on a water-resistant level surface 2-3 feet off of floor. |
Water dripping when refiling. | Water remaining on bottom of tank. Wipe tank or tilt to drain beforetransporting. Make sure tank cap is secured tightly. |
Increased noise level. | Unit must be placed on a flat, level, hard surface. Make sure it is NOT placed on a soft or absorbent surface |
SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
![]()
Failure to comply with the warnings listed below may result in electric shock or serious injury.
This product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.
![]()
To reduce the risk of severe burns, keep this product out of the reach of childrenand pets. - Disassembly, repair or remodeling by an unauthorized person may result in serious harm and wil void the manufactures warranty.
- Always place this humidifier on a firm, flat & level surface. This humidifier may not work properly on an uneven surface.
- Do not place this product on cloth, carpet or an absorbent surface. This may block air inlet.
- This product releases mist. Do not place this humidifier directly on wood furniture, flooring or anysurfaces that could be damaged by water. Manufacturer does not accept any liability for damage in the case of the unit being placed incorrectly.
- Do not use if the plug is damaged or loose.
- Before filing or cleaning the unit, make sure it is unplugged.
- Once the humidifier has been plugged in, do not tilt or move the unit.
- Do not handle the plug with wet hands.
- Do not excessively bend, twist, pul or damage the power cord.
- Avoid placing this product where the humidity spout is pointed directly at an object or person.
- Do not inhale the mist/vapor expeled from the product or drink water from the tank.
- Do not fil the water tank with hot or boiling water.
- Do not use this product in direct sunlight or near a heat source such as a stove, heater or radiator.
- If the water tank becomes cracked or damaged, do not use.
- Do not keep this product running for an extended period of time.
- Unplug the cord when unit is not in use for an extended period of time and/or when no one is home.
- Do not keep water in the tank when not in use for an extended period of time.
- Do not clean the unit, water tank or water reservoir with detergents or chemicals of any kind.
- The use of water additives in the tank including ethereal/essential oils, fragrances, eucalyptus, water conditioners, etc. wil damage the appliance materials and as a consequence the whole unit. Any use of such additives in the tank wil void the manufactures warranty.
- Do not use this product near any other electronic device.
- Do not cover the spray spout at any time during use. Do not put anything on or in the tank.
![]()
Neither humans nor animals can hear the high frequency vibrations. - When unplugging from outlet hold humidifier securely.
- Do not place cord over objects.
- Do not get water in or on the power cord or where it connects to the product.
- Do not use near a sink.
- Do not touch the water tank during operation.
- Do not submerse the unit in water or pour water on the unit or in the humidity spout.
- When emptying water from water tank, pour on drain side.
- Do not cover the spout with cloth or hand and do not use without the spout.
- Use clean or distiled water in tank. Hard water areas wil require more frequent cleaning. Stop using your humidifier and contact your physician if you have respiratory symptoms which you believe are associated with periods of use of your home humidifier, even if you are folowing maintenance directions.
![]()
This product can expose you to chemicals including lead or lead compounds, which are known to the State of California to cause cancer or birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov.
Customer Service
1.866.603.590026251
www.guardiantechnologies.com
![]()
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Need help?
Do you have a question about the H3250 and is the answer not in the manual?
Questions and answers