  • Page 1 I N S T R U C T I O N M A N U A L H I G H V A C U U M HVU Lite 300 www.geovent.com Version 1.0 08.05.2023...
  • Page 3: Table Of Contents

    Do not modify the product or use spare parts from other suppliers than Geovent, as this may hamper the product The manual must be read in full and understood before and the function.
  • Page 4: Machine Overview

    Filter areal effect accor- Model Vakuum [m²] ding to [kPa] BIA-test The Geovent HVU Lite 300 is a compact high vacuum unit for collecting dust, fumes or other particles. HVU Lite 300 99,9% 3.2 Intended use Sound Compres- pressure sed air...
  • Page 5: Assembly, Installation And Start Of Operation

    5.0 Assembly, installation and start of Luft ud Air out operation 5.1 Location Air in Luft ind To ensure a flawless function, the product must be in- stalled indoors in e.g. an engineering room with sound Aftappehane Drain tap 30 mm insulation ventilation.
  • Page 6: Commissioning

    Adjustment of the vacuum safety device • The annular chamber blower/motor is in principle main- Adjust so that the valve does not open during normal tenance free due to the factory sealed special ball bea- operation, but opens when blocked. rings. www.geovent.com Side 3/6...
  • Page 7: Replacing Filter

    8.0 Cleaning Replacement of worn bearings should only be carried out by a qualified service technician. The outside of the product is cleaned with a vacuum 7.3 Replacing filter cleaner or a cloth. 7.3.1 Emptying of bucket 9.0 Troubleshooting Emptying of the collection bucket should be done In the event that problems occur, the following items when it is approx.
  • Page 8: Dimensions

    Ø76mm 670mm 670mm 275mm 275mm User liability In order for Geovent to be capable of granting the decla- red warranty, the user/fitter must follow this instruction manual in all respects. Under no circumstances may the products be chan- Ø76mm Ø76mm ged in any way, without prior written agreement with Geovent A/S.
  • Page 9: Declaration Of Conformity

    13-727 AirBox Lite HV Model: HVU Lite 300 HVU Lite 300 FRQ Complies with the relevant parts of the following directi- ves and standards: Directive 2006/42 / EC of the European Parliament and of the Council of 17 May 2006 on machines and amen- ding directives 95/16 / EC.
  • Page 10 Principle drawing...
  • Page 12 HOVEDGADEN 86 • DK-8831 LØGSTRUP (+45) 8664 2211 • salg@geovent.dk...