Parameter
No.
Description
Oil: Maximum oil pressure switch / POC Input
0 = deactivated
277
1 = Maximum oil pressure switch
2 = POC
Oil: selection transformer ignition phase TA
281
0 = brief pre-ignition (Ph38)
1 = long pre-ignition (with fan)(Ph22)
284
Oil: Post-purging time (t3)(at deactivation of the load (LR)) - ON
400
AIR / FUEL MODULATION CURVES
401
Checking fuel servomotor (only setting of the curve)
402
Checking air servomotor (only setting of the curve)
500
POSITIONING OF SERVOMOTORS
Position of the fuel servomotor in absence of flame
Index 0 = standby position
501
Index 1 = pre-purging position
Index 2 = post-purging position
Position of the air servomotor in absence of flame
Index 0 = standby position
502
Index 1 = pre-purging position
Index 2 = post-purging position
Minimum modulation limit
545
Not defined = 20%
Maximum modulation limit
546
Not defined = 100%
600
SERVOMOTORS
Tolerance limit for position check (0.1°)
Index 0 = fuel
Index 1 = air
606
More serious position error, where a defect has cer-
tainly been detected
- > Stop range: (P 606 - 0.6°) a P606
Analogue exit configuration
0 = DC 0...10 V
645
1 = DC 2...10 V
2 = DC 0 / 2...10 V
700
LOG OF THE ERRORS
701
Error chronology: 701-725.01.Code
Error chronology: 701-725.02.Diagnostic code
Error chronology: 701-725.03.Error class
Error chronology: 701-725.04.Phase
Error chronology: 701-725.05.Start-up meter
725
Error chronology: 701-725.06.Load
900
PROCESS INFORMATION
Actual output
903
Index 0 = fuel
Index 1 = air
Position of the servomotors
922
Index 0 = fuel
Index 1 = air
Heat source active
1 = output during the definition of the curves
2 = manual output
942
3 = BACS output
4 = analogue input output
5 = output of the external load regulator contacts
Control and display
Unit of
No. of
Modifica-
measure-
elements
tion
ment
1
-
Modification
1
-
Modification
1
s
Modification
13
(°)
Modification
13
(°)
Modification
3
(°)
Modification
3
(°)
Modification
Modification /
1
%
zero setting
Modification /
1
%
zero setting
2
(°)
Modification
1
-
Modification
25
-
Reading only
25
-
Reading only
25
-
Reading only
25
-
Reading only
25
-
Reading only
25
%
Reading only
2
%
Reading only
2
(°)
Reading only
1
-
Reading only
51
GB
Values interval
Degree of
precision
Min.
Max.
1
2
1
0
1
1
1s
108 min
0.2s
90°
0.1°
90°
0.1°
90°
0.1°
90°
0.1°
20%
100%
0.1%
20%
100%
0.1%
0.5°
0.1°
0
2
1
0
255
1
0
255
1
0
6
1
0
255
1
0
99999999
1
0%
100%
0.1%
0%
100%
0.1%
-50°
150°
0.01°
0
255
1
Predefined
Access mode
setting
1
Service Mode
1
Service Mode
1s
Service Mode
0°; 0°; 15°;
Service Mode
Not defined
0°; 90°; 45°;
Service Mode
Not defined
0°; 0°; 15°
Service Mode
0°; 90°; 45°
Service Mode
Not defined
Service Mode
Not defined
Service Mode
1.7°; 1.7°
Service Mode
2
Service Mode
0
Info mode
0
Info mode
0
Info mode
0
Info mode
0
Info mode
0%
Info mode
0%
Info mode
Info mode
0
Service mode
20205886