Sign In
Upload
Manuals
Brands
Riello Manuals
Indoor Fireplace
RS 68/E LN
Riello RS 68/E LN Manuals
Manuals and User Guides for Riello RS 68/E LN. We have
2
Riello RS 68/E LN manuals available for free PDF download: Installation, Use And Maintenance Instructions
Riello RS 68/E LN Installation, Use And Maintenance Instructions (40 pages)
Forced draught gas burners
Brand:
Riello
| Category:
Burner
| Size: 6 MB
Table of Contents
Table of Contents
3
Information and General Instructions
5
Information about the Instruction Manual
5
Introduction
5
General Dangers
5
Other Symbols
5
Guarantee and Responsibility
6
Owner's Responsibility
6
Safety and Prevention
7
Introduction
7
Personnel Training
7
Technical Description of the Burner
8
Technical Data
8
Electrical Data
8
Burner Models Designation
9
Burner Equipment
9
Burner Dimensions
10
Firing Rates
10
Procedure to Refer Burner Operating Condition at an Altitude And/Or at a Combustion Supporter Air Temperature Different to the Standard Values (328 Ft above Sea Level, 68 °F)
11
Minimum Furnace Dimensions
12
Commercial Boilers
12
Burner Description
13
Control Box for the Air/Fuel Ratio (LMV37.4
14
Actuators (SQM33.5
17
Installation
18
Notes on Safety for the Installation
18
Handling
18
Preliminary Checks
18
Operation Position
18
Preparing the Boiler
19
Boiler Plate
19
Securing the Burner to the Boiler
19
Electrode Positioning
20
Combustion Head Calibration
20
Adjustment of the Combustion Head
21
Air Adjustment
21
Gas Adjustment
21
Burner Refitting
22
Gas Supply
23
Gas Train
23
Gas Feeding Line
23
Gas Supply Pressure
24
Electrical Wiring
25
Thermal Relay Calibration
26
Electro-Mechanical Thermal Relay
26
Electronic Thermal Relay
26
Motor Connection at 208-230 or 460V
27
Motor Connection at 575V
27
Reversible Direction
27
Start-Up, Calibration and Operation of the Burner
28
Notes on Safety for the First Start-Up
28
Operations before Start-Up
28
Burner Start-Up
28
Adjusting Gas/Air Delivery
29
Final Calibration of the Pressure Switches
29
Air Pressure Switch
29
Maximum Gas Pressure Switch
29
Minimum Gas Pressure Switch
30
Flame Signal Measurement
30
Final Checks (with the Burner Working)
30
Maintenance
31
Notes on Safety for the Maintenance
31
Maintenance Programme
31
Maintenance Frequency
31
Safety Test - with Gas Ball Valve Closed
31
Checking and Cleaning
31
Safety Components
32
Opening the Burner
33
Closing the Burner
33
A Appendix - Spare Parts
34
B Appendix - Accessories
37
Appendix - Burner Start up Report
38
Advertisement
Riello RS 68/E LN Installation, Use And Maintenance Instructions (40 pages)
Forced draught gas burners, Progressive two-stage or modulating operation
Brand:
Riello
| Category:
Indoor Fireplace
| Size: 2 MB
Table of Contents
Table of Contents
3
1 Information and General Instructions
5
Information about the Instruction Manual
5
Introduction
5
General Dangers
5
Danger: Live Components
5
Guarantee and Responsibility
6
Owner's Responsibility
6
2 Safety and Prevention
7
Introduction
7
Personnel Training
7
3 Technical Description of the Burner
8
Technical Data
8
Burner Models Designation
8
Electrical Data
9
Three Phase Burner
9
Three Phase Burner
10
Burner Description
11
Burner Equipment
11
Packaging - Weight - Approximate Measurements
12
Burner Dimensions
12
Firing Rates
13
Procedure to Refer Burner Operating Condition in High Altitude Plants
13
Control Box for the Air/Fuel Ratio (LMV37.4
15
Actuators (SQM33.5
18
4 Installation
19
Notes on Safety for the Installation
19
Handling
19
Preliminary Checks
19
Operation Position
19
Securing the Burner to the Boiler
20
Boiler Plate
20
Boiler Fixing
20
Electrode Positioning
21
Combustion Head Calibration
21
Adjustment of the Combustion Head
22
Air Adjustment
22
Gas Adjustment
22
Gas Train Assembly
24
Gas Feeding Line
24
Gas Supply Pressure
25
Electrical Wiring
26
Notes on Safety for the Electrical Wiring
26
Thermal Relay Calibration
27
Electro-Mechanical Thermal Relay
27
Electronic Thermal Relay
27
Motor Connection at 208-230 or 460V
28
Motor Connection at 575V
28
Reversible Direction
28
5 Start-Up, Calibration and Operation of the Burner
29
Notes on Safety for the First Start-Up
29
Operations before Start-Up
29
Burner Start-Up
30
Final Calibration of the Pressure Switches
31
Air Pressure Switch
31
Maximum Gas Pressure Switch
31
Minimum Gas Pressure Switch
31
Flame Signal Measurement
32
Final Checks (with the Burner Working)
32
6 Maintenance
33
Notes on Safety for the Maintenance
33
Maintenance Programme
33
Maintenance Frequency
33
Checking and Cleaning
33
Opening the Burner
34
Closing the Burner
34
A Appendix - Spare Parts
35
B Appendix - Accessories
38
C Appendix - Burner Start up Report
39
Advertisement
Related Products
Riello RS 68/M LN
Riello RS 68/M BLU
Riello RS 68/E FGR
Riello RS 610/M MZ
Riello RS 610/EV BLU FS2
Riello RS 610/E O2 BLU
Riello RS 610/EV FGR
Riello RS 610/E ULX
Riello RS 650
Riello RS 610/E FGR
Riello Categories
Burner
Boiler
Indoor Fireplace
UPS
Air Conditioner
More Riello Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL