IPM and over current error (cont.)
Is the resistance between the
Compressor body and chassis Maga Ω?
Are the location of the
temperature sensor and measurement value
Is the connection
cable between the compressor and PCB
properly connected?
Replace PCB
4-20
Continued
Yes
normal?
Yes
Yes
No
No
No
correct the sensor location or replace it
Replace compressor
Turn off the power then
reconnect the cable
Turn off the power then
Samsung Electronics