Technical Data - Sub-Zero IC-30RID-RH Use And Care Manual

Table of Contents

Advertisement

Available languages

Available languages

T E CH NI CA L DATA
Sub-Zero Water Filtration System Data
IMPORTANT NOTICE: Read this Performance Data Sheet carefully and compare the capabilities of this unit with your actual water treatment needs.
It is recommended that, before purchasing a water treatment unit, you have your water supply tested to determine your actual water treatment needs.
System tested and certified by NSF International against NSF/ANSI Standard 42 and 53 for the reduction of substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit
for water leaving the system, as specified in NSF/ANSI 42/53.
Contaminant
Average Influent
Reduction*
Concentration
Chlorine, Taste & Odor
2.0 mg/L
Normal Particulate
13,666,667
Class I, ≥0.5 to <1.0 μm
pts/ml
Asbestos
96 MF/L
Atrazine
0.010 mg/L
Benzene
0.014 mg/L
Carbofuran
0.08 mg/L
Cyst**
122,500 cysts/L
Lead at pH 6.5
0.153 mg/L
Lead at pH 8.5
0.150 mg/L
Lindane
0.002 mg/L
Mercury at pH 6.5
0.006 mg/L
Mercury at pH 8.5
0.006 mg/L
Toxaphene
0.015 mg/L
Turbidity
10.8 NTU
P-Dichlorobenzene
0.215 mg/L
*Contaminant reduction determined by NSF testing. **Based on the use of Cryptosporidium Parvum oocysts.
APPLICATION GUIDELINES / WATER SUPPLY PARAMETERS
Capacity: certified for up to 750 gallons
Service Flow: 0.78 gpm
(2.95 Lpm)
Water Supply: potable water
Water Pressure: 35–120 psi
(2.8–8.2 bar)
Water Temperature: 40°F–100°F
SPECIAL NOTES
Replacement Sub-Zero water filter cartridges can be ordered online at subzero.com/store, or contact customer care at 800-222-7820.
It is recommended that the filter cartridge be replaced when the indicator is displayed, if there is a noticeable drop in pressure, the ice cubes
become hollow, or every 12 months, whichever comes first. Replacement filter pricing information can be found at subzero.com/store.
This filter must be installed, operated, maintained and replaced as required in order for the product to perform as advertised.
Note that while the testing was performed under standard laboratory conditions, actual performance may vary. The contaminants or other
substances removed or reduced by this water treatment system are not necessarily in your water.
Manufactured for: Sub-Zero, Inc., P. O. Box 44848, Madison, WI 53744, 800-222-7820
NSF Specified
Challenge
Concentration
2.0 mg/L ± 10%
At least 10,000
particles/ml
10
7
to 10
8
fibers/L
0.009 mg/L ± 10%
0.015 mg/L ± 10%
0.08 mg/L ± 10%
Min 50,000 cysts/L
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.002 mg/L ± 10%
0.006 mg/L ± 10%
0.006 mg/L ± 10%
0.015 mg/L ± 10%
11 ± 1 NTU
0.225 mg/L ± 10%
; up to twelve months
(2,839 L)
(5°C–40°C)
Product Water Concentration
Average
% Reduction
Average
Max Permissable
97.5%
0.05 mg/L
98.9%
143,333 pts/ml
>99%
<1 MF/L
89.3%
0.001 mg/L
96.3%
0.005 mg/L
86.6%
0.01 mg/L
99.99%
1 cyst/L
99.3%
0.001 mg/L
99.3%
0.001 mg/L
97.8%
0.00004 mg/L
95%
0.0003 mg/L
88%
0.0007 mg/L
93.2%
0.001 mg/L
98.7%
0.153 NTU
99.7%
0.0005 mg/L
Fibers greater than 10 μm in length.
NSF Reduction
Requirements
N/A
≥50%
N/A
≥85%
N/A
≥99%
0.003 mg/L
N/A
0.005 mg/L
N/A
0.04 mg/L
N/A
N/A
≥99.99%
0.010 mg/L
N/A
0.010 mg/L
N/A
0.0002 mg/L
N/A
0.002 mg/L
N/A
0.002 mg/L
N/A
0.003 mg/L
N/A
0.5 NTU
N/A
0.075 mg/L
N/A
subzero.com | 17
NSF Test
Report
J-00056501
J-00056506
J-00056511
J-00056512
J-00056535
J-00056537
J-00056513
J-00056515
J-00058784
J-00058969
J-00058785
J-00058783
J-00056531
J-00058972
J-00056538

Advertisement

Table of Contents
loading

Table of Contents