Close the Door and Dreg Drawer
The indication DOOR change from "N" to "Y"
ERROR: The indication DOOR does not change; check
the Microswitch for the door and the wiring (JP14).
Note: without the Dreg Drawer correctly inserted the DOOR indica-
tion cannot change!
Close the Beans door (only for 120V)
The indication BEAN-C change from "N" to "Y"
ERROR: The indication BEAN-C does not change; check the
reed for the door and the wiring (JP25)
Press Z7 "
6/15
P/PP
The machine passes to the Page 3 (BU PAGE)
Start condition
Press the Z1 button to move the BU to Work
IMPORTANT NOTE: If the DREGDRAWER is not inserted or the
DOOR is not closed the BU test cannot be performed. If these 2
inputs are not in the right position, a warning message will be
shown and the display turns to red.
When the BU reaches the work position the indication WORK chang-
es from "N" to "Y", the number of the current is less than 200mA
(without BU) or 300mA (with BU).
ERROR: The indication WORK doesn't change and remain "N",
the display backlight changes from white to red; Check the work
microswitch (broken?), the BU motor (blocked?) and the wiring
(JP16).
ERROR: (Without BU) The absorbed current is more than
200mA, the display backlight changes from white to red; check the
BU and the motor.