Specifications

Pressures
Maximum Static Pressure
Maximum Maintained Pressure
Minimum Maintained Pressure
(Gas Water Heater)
Minimum Maintained Pressure
(Gravity System)
Temperatures
Close temperature control
Optimum Thermostatic Control
Range
Recommended Hot Supply
Minimum Hot Water Supply Tem-
perature
Minimum Recommended
Differential between Hot Supply
and Outlet Temperature
Cold Water Range
Plumbing Connections
Hot: Left
Cold: Right
Outlet:
Important! This product is not suitable to use with any other pipe sizes.
Thermostatic Shut-down
For safety and comfort the thermostat will shut off the mixing valve within
2 Seconds if either supply fails (achieved only if the blend temperature has a
minimum differential of 12°C from either supply temperature).
1553346-W2-A
1000 kPa (10 bar)
500 kPa (5 bar)
100 kPa (1 bar)
(for optimum performance supplies should be
nominally equal)
10 kPa (0.1 bar)
(0.1 bar = 1 Metre head from cold tank base to shower
handset outlet)
20°C - 50°C
35°C to 45°C
(achieved with supplies of 15°C cold, 65°C hot and
nominally equal pressures)
60°C to 65°C
55°C
(Note: The mixing valve can operate at temperatures
up to 85°C for short periods without damage.
However for safety reasons, it is recommended
that the maximum hot water temperature is limited
to 65°C).
12°C at desired flow rates
1 - 25°C
15 mm compression fitting
15 mm compression fitting
Single Outlet = 1/2" BSP Male to flexible house
8