Important Instructions; Specifications - Kohler K-682 Installation Manual

Digital thermostatic valve
Hide thumbs Also See for K-682:
Table of Contents

Advertisement

Available languages

Available languages

IMPORTANT INSTRUCTIONS

WARNING: When using electrical products, basic precautions should always be followed,
including the following:
WARNING: Risk of electric shock. A qualified electrician should route all electrical wiring.
WARNING: Risk of electric shock. Disconnect power before servicing.
WARNING: Unauthorized modification may cause poor performance of the valve. Do not make
modifications to the valve as this could adversely affect the performance of the valve and void the
warranty. Kohler Co. shall not be liable under its warranty or otherwise for personal injury or
damage caused by any such unauthorized modification.
WARNING: Risk of injury or property damage. Please read all instructions thoroughly before
beginning installation.
NOTICE: Follow all plumbing, electrical, and building codes.
NOTICE: Some electrical codes require a circuit protected by a Ground-Fault Circuit-Interrupter (GFCI)*.
NOTICE: Provide unrestricted service access to the valve.
*Outside North America, this device may be known as a Residual Current Device (RCD).
___________________________________________________________________________________________________
Operation with DTV, DTV II, or DTV+
DTV: The valve is controlled from one or two user interfaces that connect directly to the valve.
DTV II: To connect the valve to the DTV II system, the K-638 media module is required.
DTV+: To connect one or two valves to the DTV+ system, the K-99695 system controller and
K-97172 data cable(s) are required.
Refer to the appropriate sections in this guide for your system configuration.
Specifications
Pressures
Maximum Static Pressure
Supply Pressure Differential*
Minimum Flow Rate
Temperatures
Programmable Temperature
Default Temperature at Start-up
Minimum Mixed Temperature
Differential from Hot Supply
Optimum Thermostatic Control Range
Temperature Stability at Recommended
Supply Conditions
Ambient Temperature
Maximum Relative Humidity
Electrical
1043183-2-E
125 psi, 862 kPa, 8.6 bar
Max 5 psi, 34.5 kPa, 0.34 bar differential Hot pressure should be equal
to or less than cold pressure.
1.6 gal/min (Less than 72 psi dynamic pressure.)
6 l/min (Less than 500 kPa maintaining pressure.)
2.1 gal/min (Greater than 72 psi dynamic pressure.)
8 l/min (Greater than 500 kPa maintaining pressure.)
Max 120°F (49°C) Min 79°F (26°C) Full cold may also be selected.
102°F (39°C)
3.6°F (2°C)
86°F (30°C) to 120°F (49°C)
+/- 1.6°F (1°C)
Greater than 34°F (1°C), Max 104°F (40°C)
95% non-condensing
2
Kohler Co.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents