Troubleshooting - EINHELL 41.405.50 Operating Instructions Manual

Hide thumbs Also See for 41.405.50:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
Anleitung_RT_HP_1855_TR_SPK1:_
9. Possible causes of failure

Troubleshooting

Device does not work
The motor starts but there is no
build up of pressure
Irregular operating pressure
The device suddenly stops working - Motor circuit breaker has been
19.11.2008
13:33 Uhr
Cause
- No electrical voltage at the
device.
- Cross section of the extension
cable not large enough and/or
the extension cable is too long.
- The mains voltage is lower than
that specified.
- Motor circuit breaker has been
triggered.
- The pump is frozen.
- The water intake filter is
clogged.
- Air intake in the water inlet.
- Discharge nozzle is too large.
- Air intake in the water inlet.
triggered.
Seite 15
Remedy
- Check the fuse, power cable and
power plug and have them
replaced by qualified personnel
if necessary.
- Use extension cables with larger
cross sections and/or use
shorter extension cables.
- Contact the power supply
company if necessary.
- Wait 5 - 10 minutes. (see point
7.2.4)
- Check and thaw if necessary.
- Clean the water intake filter.
(see 7.2.1).
- Check the supply hose and hose
connection and replace if
necessary.
- Check and replace if necessary.
- Check the supply hose and hose
connection and replace if
necessary.
- Wait 5 - 10 minutes. (see point
7.2.4)
GB
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rt-hp 1855 tr