Connectors - RFI RX1317-3408-31 Series User Manual

Receiver multicoupler
Table of Contents

Advertisement

Receiver Multicoupler User's Manual

13. Connectors

DC Power connector (Phoenix 2-pin) pin-out:
The pin numbers on the polarized Phoenix 2-pin connector on the rear of the RxMux are illustrated below.
Pin Function Table:
Pin
1
2
Alarm connector (Phoenix 3-pin) pin-out:
The pin numbers on the polarized Phoenix 3-pin connector on the rear of the RxMux are illustrated below.
Pin Function Table:
Pin
1
2
3
The labelling of the alarm connector pins on the rear of early serial number RxMux units is "NC" and "CMN". This
Note:
represents the alarm relay pin designations, not its contact's operational state. In these early serial number units the "NC"
and "CMN" connections on the alarm connector would measure as an open-circuit under normal operation (i.e. no alarms)
and a short-circuit (or "closed") when an alarm is present. Later serial number RxMux units had this naming discrepancy
clarified by changing the labelling of the alarm connector pins changed to "NO" and "CMN" to reflect the relay contact's
operational state.
Figure 16 – DC Power Pinout
Function
DC Power Input -ve
DC Power Input +ve
Figure 17 –Alarm Pinout
Labelling
Function
Fault – Closed when an alarm is present
NO
Fault – Open when an alarm is present
-
CMN
Common
Asia Pacific | EMEA | Americas
Table 7
Table 8
32

Advertisement

Table of Contents
loading

Related Products for RFI RX1317-3408-31 Series

This manual is also suitable for:

Rx3852-3408-31 seriesRx6996-3408-31 series

Table of Contents