2100 SERIES INSTALL GUIDE
DIRECT-WIRED ROOM HEATER
NOTE: Always transport the heater in an upright
position to avoid damage to internal components
and insulation materials.
1
PERSONAL SAFETY INSTRUCTIONS
SAFETY ALERT SYMBOLS
Three safety alert symbols are used to alert you to
personal safety instructions. They are:
Electrical (1)
Mechanical (2)
Fire (3)
SIGNAL WORDS
Signal words that appear next to safety alert symbols are:
DANGER
WARNING
CAUTION
IMPORTANT
NOTE
Carefully read and understand the instructions before you continue.
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
Important
The equipment described herein is intended for installation by a qualified technician in compliance with
applicable local, state, and national codes and regulations.
Disclaimer: In compiling this manual, Steffes has used its best judgement based upon information
available, but disclaims any responsibility or liability for any errors or miscalculations contained herein,
or any revisions hereof, or which result, in whole or in part, from the use of this manual or any revisions
hereof.
2
SAFETY PRECAUTIONS
1. DO fully assemble the heater before energizing.
2. DO keep all explosive materials and/or flammable gases away from the heater.
3. DO maintain the placement and clearance requirements (Section 4).
4. DO keep items away from the discharge air grill area of the heater.
5. DO contact a qualified service technician for installation of this heater to ensure it is installed in accordance with
information contained herein and with national, state, and local codes and requirements.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2100 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Steffes 2100 Series

  • Page 1 • Disclaimer: In compiling this manual, Steffes has used its best judgement based upon information available, but disclaims any responsibility or liability for any errors or miscalculations contained herein, or any revisions hereof, or which result, in whole or in part, from the use of this manual or any revisions hereof.
  • Page 2: Determine Installation Location

    IDENTIFY HEATER TYPE Steffes heaters are available for connection to different input voltages. Standard configuration for direct-wired heaters is 240V; cord-connected heaters are configured to plug into a 120V wall outlet. To determine the configuration of the heater, refer to the Unit Identification Label on the lower left side panel. All heaters are UL and cUL safety listed.
  • Page 3: Installation

    INSTALLATION 1. Remove the heater from the box and lift it off the shipping pallet. WARNING Place the shipping box aside until the brick loading process (Section 9). Risk of fire. Can cause injury or death. 2. Locate Install Guide, registration card, and brick loading tool. Failure to secure the heater can cause These items are shipped on the top of the heater.
  • Page 4: Line Voltage Connections

    2100 Series heaters are equipped with a two-circuit element feed option and a blower/control circuit. Refer to the Unit Identification label for proper sizing of each circuit. If single-circuit connection is used, size the circuit for total wattage (Charge Crct #1 + Charge Crct #2 + Blower/Cntrl Crct = Total Wattage).
  • Page 5 TIME CLOCK MODULE PEAK CONTROL The Steffes Time Clock Module (part #130104) is another option for providing a peak control signal to the heater. Peak control times are programmed into the heater to enable this device. Refer to the instructions provided with the time clock module for more information on the installation and operation of this device.
  • Page 6 The heater responds by automatically storing heat in its brick core according to outdoor temperature and the heating requirements. f connecting to the Steffes power line carrier (PLC) system, refer to the PLC Installation Methods: A) Hard-wired to the heater (one sensor Owner’s and Installer’s Guide.
  • Page 7: Configuration Menu

    Row 1 SIDE VIEW CONFIGURATION MENU IMPORTANT The Steffes 2100 Series room heaters have a Configuration If access to Configuration Menu times Menu, which allows the heaters to be customized for the out, the heater must be powered off equipment installed and the power company consumers’...
  • Page 8: Installer's Final Check-Out Procedure

    10.8 45.00 (Amp draw is calculated by taking the total input wattage divided by the input voltage. Allow +/- 5% tolerance at nominal input voltage.) 3050 Hwy 22 North | Dickinson, ND 58601-9413 USA| www.steffes.com Part No. 1206094 Rev. 1...