Installation Instructions - Prodew FogMist Track System Installation Manual

System for produce cases
Hide thumbs Also See for FogMist Track:
Table of Contents

Advertisement

STEP 1
• Mount the mist control box, air compressor, and timer box
at the center of the area being misted on top of the case.
• Other mounting locations can be used.
STEP 2
• Mount the clamp lock into the case ceiling in the area to
be fogged with the provided screws.
• Preferably inside the air curtain.
• Use the Track Mounting Options on page 6 for location
ideas.
STEP 3
• Spread the lines across the area which needs fogging.
• Use 3/4in tubing on the track line to hold the lines into the
clamp (try not to twist the lines as you install).
• For two or more sets of lines, the feed location should be
together for two lines.
• Once the lines are held in place, ensuring that all tubing
fits into the clamp.
• The covers will fit in between the nozzle and shutoff valves
(some trimming and cutting may be needed for feed lines).
STEP 4
• Drill a hole for the feed lines in the case ceiling behind the
track (approximately 6in).
• Ensure that no water, air, electrical or refrigerated lines are
in the way.
• Insert a piece of corrugated tubing into the hole.
STEP 5
• Run the 6mm air and water tubing through the corrugated
tubing. Cut to length.
• Connect the 6mm air and water tubing to the 3/8in air and
water tubing using the 3/8in to 6mm reducing coupler.