INSTALLING THE WALL CONTROL

REMEMBER to turn off the power before you begin.
NOTE - Secures to any surface or application: flat wall, single gang
box, multi gang box.
Option 1. Flat Surface Installation
1
Select a desired location. Use the wall plate to mark the
location of the mounting holes. Plastic wall anchors or
mounting screws are needed for this application. (Fig. 1)
Seat the cradle B into the wall plate. Secure the wall plate
2
to the wall using the provided hardware.
3
Snap the face plate cover onto the wall bracket.
4
Remote transmitter will be held in place with built in magnets.
Cradle B
Wall plate
Plastic
anchor
Wall
Fig. 1
HIRO Control System
Option 2. For single gang box
1
2
3
4
5
6
Face plate
Transmitter
Fig. 2
Remove the existing wall plate and the old switch from the
wall outlet box.
Seat the cradle A into the wall plate. (Fig. 2)
Connect the black lead wires from the switch in the cradle A
to the black wires in the switch box. Hot input wire to one of
the cradle A switch leads. Power lead to the fan is connected
to the remaining switch lead.
Connect the wall plate/cradle A assembly to the wall outlet
box using the supplied hardware.
Snap the face plate cover onto the wall bracket.
Remote transmitter will be held in place with built in magnets.
Outlet box
Wall plate
Cradle A
Face plate
Transmitter