Maintenance

General Troubleshooting

Symptom
No output / short output
No output / spitting fluid
Fuse keeps blowing
Product does not power
on
Product stops pumping
Loud noise
If problems persist after attempting the solutions above, contact Chauvet Technical
Support.
Hurricane 1000 User Manual Rev. 3
Possible Cause
Line blockage
Air in fluid line
Incorrect fluid
Incorrect fluid
Blocked pipes
Failing part
Excessive load on the
circuit
Short circuit along the
power lines
No energy on power
outlet
Loose power cord
Damaged power cord
Blown fuse
Internal problem
Low / no fluid
Possible Solution
Ensure there is fluid in the tank.
Turn the product 45° to flatten out the bubble
and allow the fog fluid to flow properly.
Unplug the product for 5 seconds, then plug it
back in. Repeat as necessary.
Note: after 10 attempts, contact Chauvet
Technical Support..
Clean thoroughly with Chauvet FCQ (see
Machine
Maintenance). Refill with Chauvet
water-based fog fluid.
Contact Chauvet Technical Support.
Ensure the total load does not exceed 80% of
the breaker or fuse nominal current.
Check the power lines and power cords.
Check the power outlet.
Change to another outlet.
Check the power cord.
Replace the blown fuse with an intact fuse of the
same type and rating.
Send product for repair.
Refill with Chauvet water-based fog fluid.
Fog