Grundfos CRE Series Installation And Operating Instruction page 17

Table of Contents

Advertisement

Terminal
C2
NO
RJ45
GND
DI3
24V
AI2
5V
GND
TX
RX
GND
DI4
PT2
PT1
LT1
GND
LT2
5V
A
Y
B
AI1
DI1
24V
GND
AO1
GND
AI3
DI2
S24
ST1
ST2
Type
Common
Normally open contact
Ethernet
GND
DI3/OC1
+24 V
AI2
+5 V
GND
GDS TX
GDS RX
GND
DI4/OC2
Pt100/1000 input 2
Pt100/1000 input 1
LiqTec sensor input 1
GND
LiqTec sensor input 2
+5 V
GENIbus, A
GENIbus, Y
GENIbus, B
AI1
DI1
+24 V
GND
AO
GND
AI3
DI2
+24 V (STO)
STO1
STO2
Function
Ethernet communication
Signal ground
Digital input/output, configurable
Open collector: Maximum 24 V resistive or inductive
Power supply
Analog input:
0-20 mA or 4-20 mA
0.5 - 3.5 V, 0-5 V or 0-10 V.
Power supply to a potentiometer or sensor
Signal ground
Grundfos Digital Sensor output
Grundfos Digital Sensor input
Signal ground
Digital input/output, configurable
Open collector: Maximum 24 V resistive or inductive
Pt100/1000 sensor input 2
Pt100/1000 sensor input 1
LiqTec sensor input 1
White conductor
Signal ground
Brown and black conductors
LiqTec sensor input 2
Blue conductor
Power supply to a potentiometer or sensor
GENIbus, A (+) / Modbus, D1 (+)
GENIbus, GND / Modbus, GND
GENIbus, B (-) / Modbus, D0 (-)
Analog input:
0-20 mA or 4-20 mA
0.5 - 3.5 V, 0-5 V or 0-10 V.
Digital input, configurable
Digital input 1 is factory-set to be start or stop input where
an open circuit results in stop. A jumper has been factory-
fitted between terminals DI1 and GND. Remove the jumper
if digital input 1 is to be used as external start or stop or any
other external function.
Power supply
Signal ground
Analog output:
0-20 mA or 4-20 mA
0-10 V.
Signal ground
Analog input:
0-20 mA or 4-20 mA
0.5 - 3.5 V, 0-5 V or 0-10 V.
Digital input, configurable
Power supply to the Safe Torque Off inputs
Safe Torque Off - Input 1
Safe Torque Off - Input 2
17

Advertisement

Table of Contents
loading

Table of Contents