Connections; Temperature Setting - Aktakom ASE-1203 Operation And Maintenance Manual

Intelligent lead free soldering station 2 in 1
Table of Contents

Advertisement

1. Turn the unit ON and set the temperature control knob to highest. Then
wiggle and kink the iron cord at various locations along its length, including
in the strain relief area. If the LED heater lamp flickers, then the cord needs
to be replaced.
2. Check the resistance between the pin of the plug and the wire on the terminal.
8.4 Replacing the Fuse
1. Turn power switch off and take out the fuse holder at the power socket.
2. Open the fuse holder and take out the broken fuse.
3. Install a new fuse and put the fuse holder back in place.
Page 15
1. Dampen the small cleaning sponge with water and then squeeze it dry. Place
it in the iron holder base.
2. Add water to iron holder base. The small sponge will absorb water to keep
the large sponge above it wet.
3. The large sponge may be used alone (without small sponge & water).
Dampen the large cleaning sponge and place it on the iron holder base.

3.2 Connections

CAUTION:
Be sure to turn off the power switch before connecting or disconnecting the
soldering iron. Failure to do so may result in damage to the soldering
station.
1. Connect the cord assembly to receptacle.
2. Place the soldering iron in the iron holder.
3. Be sure to ground the unit. One end of the unit connects with the grounding
hole at the back of the unit, and the other end connects with the earth.
4. Plug the power cord into a power supply. Turn on the power switch.
5. The heater point (the radix point on the 1's right side) flickers when the
temperature has stabilized.

3.3 Temperature Setting

CAUTION:
Make sure the temperature of the station can be adjusted (Password is right
or the password is initial "000"). While setting the temperature normally,
the heating element is off.
Heater indicator
Page 4

Advertisement

Table of Contents
loading

Table of Contents