Fuel and Battery state flag explanation:
Fuel/Battery Flag Status Available Error Alarm Digital sensor
Enum (bit field) value

Euroscan

To properly use Euroscan with FMX640 these steps must be followed:
In FMX640 RS232 settings Euroscan mode is selected and Baudrate set to 38400
Partner mode enabled on Euroscan
To enable Partner mode on Euroscan :
1.
Press and hold the green button for 4 seconds
2.
Insert password. Default password - 1111
3.
Press the blue button to open 11 communication settings
4.
Press the green button to select edit action
5.
11.1.0 Com1 Port settings should be opened, then press the green button again
6.
Then search for Partner protocol and press the green button to accept changes
Important note - RX and TX are inverted via the RS-232 connection. Scheme to properly manage
Euroscan RS232 connection: Pinout of DataCold600
Available parameters (AVL IDs) with Euroscan :
External
External
Sensor
Sensor
Temperature
Temperature
1
2
484
485

Configuration

Make sure the FMB640 device is configured to receive data from "Transcan2 Reefer", "Touchprint
Reefer", "Euroscan: or "DataCold Reefer". To do this, enter the configurator window, select the
RS232 \ RS485 section displayed in the screenshots below, and configure accordingly (COM1/COM2
Settings, Mode "Transcan2 Reefer", "Touchprint Reefer", "Euroscan"or "DataCold Reefer",
0
1
External
External
Sensor
Sensor
Temperature
Temperature
3
4
486
487
2
3
External
External
Sensor
Sensor
Temperature
Temperature
5
488
Digital
Digital
Sensor
Sensor
1
2
6
489
10464 10465 10466 10467
Digital
Digital
Sensor
Sensor
3
4