Carrier Datacold 600 - Teltonika FMB640 Manual

Hide thumbs Also See for FMB640:

Advertisement

AVL ID
10695 10696 10697 10698 10699 10700
Configuration: No configuration is necessary.
See ThermoKing Configuration.

Carrier Datacold 600

To properly use DataCold 600 with FMX640 these steps must be followed:
In FMX640 RS232 settings DataCold mode is selected and Baudrate set to 38400
Partner mode enabled on DataCold 600
To enable Partner mode on DataCold 600:
1.
Press and hold the green button for 4 seconds
2.
Insert password. Default password - 1111
3.
Press the blue button to open 11 communication settings
4.
Press the green button to select edit action
5.
11.1.0 Com1 Port settings should be opened, then press the green button again
6.
Then search for Partner protocol and press the green button to accept changes
Important note - RX and TX are inverted via the RS-232 connection. Scheme to properly manage
DataCold 600 RS232 connection: Pinout of DataCold600
Available parameters (AVL IDs) with DataCold 600:
Zone 1
Parameter
Compartment
Compartment
name
state
AVL ID
10045
Parameter
Speed
Ambient Air
name
mode
Temperature
AVL ID
10071
10350
Run mode explanation:
Run mode StartStop Continious CycleCentry Unknown/Now available
Value (HEX) 0
Zone 1
Zone 1
Zone 1
Return
Supply
Zone 1 Set
Air
Air
Temperature
mode
Sensor
Sensor
10046
10047 10048
Compressor
Installation
Config
Serial
10353
10356
1
Zone 2
Zone 1
Return
Evaporator
Air
temperature
Sensor
10049
10050
10056 10057
Analog Input
Manufacturer
1-3
ID
10468-10470
10472
2
7
10701
Zone 2
Zone 3
Supply
Zone 2 Set
Compartment
Air
Temperature
state
Sensor
10058
10063
Battery
Fuel
Maintenance
State
state
1-5 Hours
Flags
flags
10473 10474 10475-10479 10480 10639 10644-10649
10702
10703
Zone 3
Zone 3 Set
Compartment
Temperature
mode
10064
10067
Run
Error
Temperature
Mode
Codes
Probe 1-6

Advertisement

loading